电感耦合等离子体质谱法(ICP-MS)测定金矿石中的金作者:宋建华来源:《科技创新导报》2020年第25期 摘 要:金礦石基体成分复杂,金的含量较低,分析时需要大称样量(≧20g),分析周 期长,干扰因素多,本文采用逆王水硝化或焙烧、50%王水溶解、2%HNO3为介质、Rh作内标,基体浓度小于1mg/mL,建立了电感耦合等离子体质谱法(ICP-MS)测定金矿石中的金的方法。试验了稀释因子100~2000时的强度干扰情况,验证了内标加入方式(离线加入法和在线加入法)对分析误差的影响,最终确定稀释因子1000、离线内标加入法可取得较好结果,方法检出限为0.04µg/g,回收率为98%~103%,测的结果与原子吸收分光光度法和传统容量法一致,能够满足地质矿的要求。 关键词:质谱法 金矿石 测金 Rh在线内标法科技创新导报
四氯化硅
蛋氨酸铬小说吕乐 中图分类号:P575 文献标识码:A 文章编号:1674-098 X (2020)09(a)-0081-03
教育督导论文 Abtract: The matrix composition of gold ore is complex, the content of gold is low, the analysis needs large sample quantity (≧20 g), the analysis period is long, and there are many interfering factors. In this paper, the method of inductively coupled plasma mass spectrometry (ICP-MS) for the determination of gold in gold ore is established by inverse nitration against aqua regia or roasting,50% aqua regia dissolved,
巴特沃斯滤波器
2% HNO3 as medium and Rh as internal standard, and the matrix concentration is less than 1 mg/mL. The intensity interference of dilution factor 100~2000 was tested, and the influence of internal standard addition (off-line addition method and on-line addition method) on the analysis error was verified. A good result can be obtained by adding sub1000 and off-line internal standard. The detection limit the method is 0.04µg/g, the recovery rate is 98~103%. The results are consistent with atomic absorption spectrophotometry and traditional capacity method, and can meet the requirements of geological prospecting.