氟硅酸钾滴定法测定高碳铬铁中的硅

氟硅酸钾滴定法测定高碳铬铁中的硅
张杰;田秀梅;戚淑芳;王莹
【摘 要】High carbon ferro-chrome was melted with KOH and KNO3 in a nickel crucible. The melting temperature was selected at 600℃ and the melting time at 10 min so that the damage to nickel crucible was reduced for the convenience of leaching. A self-designed filtration device was made by refitting an ordinary filtration bottle through replacing glass-cored funnel with plastic materials, and only 1/4 filter paper (φ=40 mm) was needed. By this method, the filtration was rapid, the filtration paper remained complete, and the residual acid amount was small, which was easy to wash and neutralize , as a result, the detection time was greatly reduced. The proposed method has been applied to the determination of high carbon ferro-chrome, the result of which agreed well with the national standard-perchloric acid dehydration gravimetric method. The relative standard deviation was smaller than 5 %.%用KOH和KNO3混合熔剂在镍坩埚中熔融高碳铬铁,选取熔融温度为600℃,熔融时间为10 min,减少了对镍坩埚的损害,易于浸取.采用自制的抽滤装置,将普通抽滤瓶进行改装,将
玻璃砂芯漏斗部分用塑料代替,只需用四分之一张滤纸(滤纸直径约为40 mm),抽滤速度快,滤纸不会穿漏,吸附的残余酸量很少,易于洗涤和中和,大大缩短了检测时间.方法用于高碳铬铁标准样品的测定,结果与国家标准方法——高氯酸脱水重量法测定结果相符,相对标准偏差小于5%.
胖九【期刊名称】《冶金分析》
【年(卷),期】2011(031)010
【总页数】4页(P70-73)
【关键词】氟硅酸钾滴定法;高碳铬铁;熔融;硅
【作 者】张杰;田秀梅;戚淑芳;王莹
【作者单位】鞍钢股份技术中心,辽宁鞍山114001;鞍钢股份质检中心,辽宁鞍山114001;鞍钢股份技术中心,辽宁鞍山114001;鞍钢股份技术中心,辽宁鞍山114001
【正文语种】中 文
【中图分类】O655.2
高碳铬铁一般是指含碳量在(6.0%~10.00%)之间,含铬量在50.0%以上的合金。高碳铬铁试样较难溶解,是由于高碳铬铁试样中的碳和氮与铬形成的碳化铬和氮化铬所致,所以高碳铬铁不易被硝酸、盐酸、硫酸溶解。为了能使试样分解完全,一般多采用碱性氧化熔剂过氧化钠,在高温条件下熔融酸化处理试样后,高氯酸发烟脱水重量法分析硅含量[1-2],且国家标准方法就是高氯酸脱水重量法[3]。此方法测定硅结果准确,对铬铁品种适应性强,但操作程序繁琐,分析周期长,大量的时间浪费在试样的熔融酸化脱水预处理过程中,测定一个试样需要12h左右,且加热蒸发冒烟时挥发的高氯酸白烟和氟化氢气体有剧毒性,影响化验员的身体健康和污染环境卫生,而且还不能满足进厂质量及生产控制对数据快速、及时的要求。
氟硅酸钾滴定法测定硅具有简便、快速、准确度高的特点。日常检验中碱熔方法分析一个样品大约3h,参考文献[4-6],将其应用在高碳铬铁中硅元素的分析,即用KOH和KNO3混合熔剂在镍坩埚中熔融高碳铬铁,经过试验,选定熔融温度600℃,在马弗炉中熔10min。合理的温度和时间,避免了试样在溶样过程中的溅出和镍坩埚的腐蚀。采用自制
的抽滤装置,使沉淀容易洗净,抽滤速度块。本方法也适用于中、低碳铬铁试样中硅的测定,为难溶试样测定硅元素提供参考。
1 实验部分
1.1 试剂及配制
硝酸钾-乙醇洗液:50g/L;氟化钾溶液:150 g/L;中性水:经煮沸后除去CO2的蒸馏水,加10滴草酚蓝指示剂,用氢氧化钠标液滴定至淡蓝;氢氧化钠标准溶液:0.1mol/L,称取4.0g氢氧化钠溶解于1 000mL无二氧化碳的水中(将水注入烧瓶中,煮沸10min,立即用装有钠石灰管的胶塞塞紧,冷却即得)[7],摇匀,保存在聚乙烯瓶中,密闭放置;氢氧化钠标准溶液标定:称取于105~110℃电烘箱中干燥至恒重的0.750 0g工作基准试剂邻苯二甲酸氢钾于250mL烧杯中,加无二氧化碳的水溶解,加2滴10g/L酚酞指示剂,用配制好的氢氧化钠溶液滴定至溶液呈粉红,并保持30s,同时做空白试验[8]。盐酸(ρ约1.19g/mL);硝酸(ρ约1.42g/mL)。
除非另有说明外,实验所用试剂均为分析纯,水为GB/T6682规定的二级水。
矩阵键盘
标准样品:高碳铬铁标样GSB03-1058-1999、GSB03-1059-1999(锦州铁合金股份有限公司);高碳铬铁标样BH0310-3(吉林铁合金股份有限公司)。
1.2 实验方法
称取0.500 0g高碳铬铁试样于镍坩埚中,加入3g氢氧化钾混匀,在电热板上低温熔融,然后再在表面盖上1g硝酸钾,徐徐加热使试样熔化后,于600℃高温炉中熔融10min。取出用沸水浸取熔融物于塑料烧杯中,加入20mL硝酸,2 mL过氧化氢,冷却至室温。在不断搅拌下缓缓加入15mL氟化钾溶液,放置10min。用双层中速滤纸(用普通滤纸剪成约Φ40mm)铺在带有塑料过滤器的抽滤瓶上抽滤,用硝酸钾-乙醇溶液洗烧杯及沉淀各2次。将沉淀及滤纸移入原烧杯中,加10mL硝酸钾-乙醇溶液,5滴溴百里酚蓝指示剂,滴加氢氧化钠标准溶液中和沉淀和滤纸上的残余酸,直至溶液呈蓝不消失。然后加入约150 mL煮沸的中性水,立即以氢氧化钠标准溶液滴定至溶液恰好变蓝为终点,记录滴定体积。随同试样做空白试验。按下式计算硅的质量分数:
式中:w(Si)—硅的质量分数,%;
c—氢氧化钠标准溶液的浓度,mol/L;
V—滴定消耗氢氧化钠标准溶液的体积,mL;散射粒子
V0—滴定空白溶液消耗氢氧化钠标准溶液的体积,mL;
m—试样质量,g;
7.02 —Si的摩尔质量,g/mol。
2 结果与讨论
2.1 熔剂的选择和用量泰鑫钢管调直机
高碳铬铁性质稳定,不溶于酸,方法的重点在于到合适的熔剂,使高碳铬铁分解,再利用氟硅酸钾滴定法测定硅的含量,常用的碱性熔剂有Na2CO3、K2CO3、NaOH、KOH、Na2O2等。按前述方法用高碳铬铁标样GSB03-1059-1999(w(Si)=2.95%)进行试验,结果见表1。
表1 熔剂的选择Table 1 Selection of flux?
纳什均衡理论由表1可见,Na2CO3、K2CO3、Na2O2熔融后的高碳铬铁,加入酸溶解后的溶液浑浊,且硅测定结果不好。这是因为Na2CO3、K2CO3熔点温度太高和Na2O2的强氧化性,使坩埚腐蚀严重,且大量的镍进入干扰测定。NaOH和KOH也能使其分解,但NaOH中的钠离子易生成氟铝酸钠沉淀,水解后释放出,使结果偏高。为此选择KOH为熔剂,KOH进入试液,经硝酸酸化即为氟硅酸的沉淀剂,有利于氟硅酸钾沉淀的形成。同时,经过试验,发现加入KNO3可以降低熔点,降低反应的剧烈程度,防止飞溅,更有利于试样的熔融,故选用KOH-KNO3混合熔剂。
长恨歌赏析

本文发布于:2024-09-20 17:30:05,感谢您对本站的认可!

本文链接:https://www.17tex.com/xueshu/580583.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:铬铁   高碳   试样   熔融
留言与评论(共有 0 条评论)
   
验证码:
Copyright ©2019-2024 Comsenz Inc.Powered by © 易纺专利技术学习网 豫ICP备2022007602号 豫公网安备41160202000603 站长QQ:729038198 关于我们 投诉建议