洛阳市区典型水体中氯离子含量调查

洛阳市区典型水体中氯离子含量调查
曾来源;刘子旬;杨岚;程燊昱;耿梦珂;蔡建川;魏学锋
【摘 要】The adaptability of the standard addition method,the standard curve method and the silver nitrate titration method for the determination of water samples were compared. The standard addition method was selected and applied to measure the chloride ion concentration in samples due to its simple operation,rapid determination and good repeatability. The experimental results showed that the chloride ion concentration of tap water, reuse water, groundwater and surface water samples was 24.01 ~42.97 mg/L, 22.37 ~47.55 mg/L, 52.97 ~59.49 mg/L and 12.07 ~52.97 mg/L, respectively. Overall, the chloride ion contents in all the collected water samples in Luoyang were lower than the environmental quality standards,which reflected the relatively good quality of water to a certain extent.%比较了标准加入法、标准曲线法和硝酸银滴定法对水样测定的适应性,结果表明标准加入法操作简单,测定速度快和重现性好;采用标准加入法对水中氯离子含量进行测定,结果表明,所采集水样中自来水、回用中水、地下水、地表水中氯离子浓度范围分别为24.01~
42.97 mg/L、22.37~47.55 mg/L、52.97~59.49 mg/L和12.07~52.97 mg/L.整体来看,所采集水样中氯离子含量未超标,一定程度反映出洛阳市水体水质良好.
dh3【期刊名称】《广州化工》
【年(卷),期】2018(046)004
【总页数】3页(P110-112)
【关键词】武汉职业技术学院图书馆氯离子;离子选择电极;标准加入法
【作 者】曾来源;刘子旬;杨岚;程燊昱;耿梦珂;蔡建川;魏学锋
【作者单位】河南科技大学化工与制药学院,河南 洛阳 471003;河南科技大学化工与制药学院,河南 洛阳 471003;河南科技大学化工与制药学院,河南 洛阳 471003;河南科技大学化工与制药学院,河南 洛阳 471003;河南科技大学化工与制药学院,河南 洛阳 471003;河南科技大学化工与制药学院,河南 洛阳 471003;河南科技大学化工与制药学院,河南 洛阳 471003
【正文语种】中 文
【中图分类】悬崖边的贵族X131.2
氯离子是水质监测的重要指标,《生活饮用水卫生标准》(GB5749-2006)[1]严格规定了不同水质氯离子的含量。其中,常规指标中氯化物的化学指标≤250 mg/L。人体饮用氯离子含量过高的自来水后,会产生毒害作用;氯离子含量过高的回用水用于植物灌溉会阻碍植物生长[2];地表水和地下水中氯离子含量过高会造成水体污染。环境状况日益严峻及环保法规的日益严格,调查常见水体中氯离子的含量意义重大[3]。
水中氯离子的测定方法有滴定法[4]、离子谱法[5]、分光光度法[6]、浊度法[7]、电位滴定法[8]、离子选择电极法[9]等。离子选择电极法包括标准加入法和标准曲线法[10]等。硝酸银滴定法[11]操作方便,但重铬酸钾指示剂毒性较大;离子谱法灵敏度较高,可一次性测定多种组分,而仪器昂贵;分光光度法精确度高,但用到较多有毒试剂;比浊法检测手段简单,但误差较大;电位滴定法的重现性和精确度高,但对人员技术要求较高;相对而言,离子选择电极法操作简单、测量精确,对环境无污染。
测量洛阳地区水中氯离子的含量,为洛阳市民的生活和生态用水安全提供基础数据。本文比较了离子选择电极法中的标准加入法和标准曲线法、硝酸银滴定法,并对洛阳市不同水
体中的氯离子含量的测定结果进行分析。
1 实 验
1.1 水样采集
洛阳市内的洛龙区、老城区、西工区、涧西区采集水样,每个水样平行采集三次,涉及到自来水、中水、地下水及地表水等,地表水和中水的采样按照《地表水和污水监测技术规范》 (HJ/T91-2002) [12]进行。
u7081.2 实验材料
pHS-3E酸度计;E-301-CpH复合电极;PCl-1-01氯离子选择电极;217-01参比电极;均由上海仪电科学仪器股份有限公司提供。
1.3 实验试剂
氯化钾、氯化钠、硝酸银、铬酸钾、均为分析纯;硝酸,65%~68%;试剂均由洛阳昊华化学试剂有限公司提供。
2 结果与讨论
2.1 三种测定氯离子方法的比较
代号x7分别采用硝酸银滴定法、标准加入法、标准曲线法对KCl标液、伊河水样进行6次平行测定,取测量平均值,并计算标准方差。
2.1.1 测定KCl标液
100 mg/L KCl标液的测定结果如表1所示。metropolis算法
表1 三种方法测定KCl标离子浓度Table 1 Chloride ion concentration in KCl standard solution determined by three methods实验方法浓度/(mg/L)标准方差硝酸银滴定法99.690.142标准加入法100.640.205标准曲线法78.815.910
由表1可见,硝酸银滴定法与标准加入法的测定结果准确性高于标准曲线法。
2.1.2 测定伊河水样
伊河水样的测定结果如表2所示。
表2 三种方法测定伊河水样中氯离子含量结果Table 2 Chloride ion concentration in Yihe water samples determined by three methods实验方法浓度/(mg/L)标准方差σ/(mg/L)硝酸银滴定法42.050.577标准加入法42.970.466标准曲线法32.380.828
由表2可知,三种方法对伊河水与KCl标液中氯离子含量的测定结果一致。综合表2、表3可知,硝酸银滴定法与标准加入法的测定结果较准确,硝酸银滴定法中消耗硝酸银因而成本高,回收过程易造成二次污染;标准加入法操作简单、检测速度快、实验重新性较好。因此,选择标准加入法对水样进行测定。
2.2 水样中氯离子含量测定
2.2.1 洛阳市区自来水中氯离子含量
采用标准加入法,测定洛阳市自来水水样中氯离子的含量,结果如表3所示。
表3 自来水样中氯离子含量
Table 3 Chloride ion concentration in tap water samples序号水样名称浓度/(mg/L)1环境监
测站自来水24.012污水厂自来水25.843洛浦公园自来水30.164理工自来水30.165科大自来水35.696牡丹园自来水42.97
由表3可见,自来水中氯离子浓度范围为24.01~42.97 mg/L。其中,牡丹园自来水的含氯量相对较高,环境监测站自来水含氯量较少。自来水中氯离子含量远小于250 mg/L,符合《生活饮用水卫生标准》(GB5749-2006)标准要求。
2.2.2 不同回用水中氯离子含量
洛阳市不同地点的回用中水的测定结果如表4所示。
表4 回用中水样中氯离子含量Table 4 Chloride ion concentration in reuse water samples序号水样名称浓度/(mg/L)7监测站中水22.378德园西区中水24.019德园东区中水27.8810污水厂二沉池中水27.8811科大中水32.7512泉舜喷泉水47.55
由表4可见,六种回用水中泉舜喷泉水含氯量最高,其余五种回用水含氯量较接近。氯离子的浓度范围为22.37~47.55 mg/L,符合《城市污水再生利用、工业用水水质》 (GB/T 19923-2005)标准(小于250 mg/L)要求[13]。
2.2.3 地下水体中氯离子含量
洛阳市地下水水样含氯量的测定结果如表5所示。
表5 地下水样中氯离子含量Table 5 Chloride ion concentration in ground water samples序号水样名称浓度C/(mg/L)13偃师泵打水52.9714黄河口井水59.49
由表5可见,偃师泵打水和黄河口井水的含氯量均为52.97~59.49 mg/L,符合《地下水质量标准》(GB/T14848-93) Ⅱ类水质标准(小于150 mg/L)要求[14]。
2.2.4 地表水体中氯离子含量
洛阳市不同地表水水样含氯量测定结果如表6所示。
表6 地表水样中氯离子含量Table 6 Chloride ion concentration in surface water samples序号水样名称浓度/(mg/L)15中州渠12.0716科大琴湖水14.3317洛河水18.3118洛龙区雨水39.0719伊河水42.9720龙门石窟水52.97
由表6可见,地表水中氯离子含量差异较大,其中伊河水和龙门石窟水样中氯离子浓度相对
最高,推测其水体杂质较多;中州渠水样中氯离子含量较低,可能是与Cl-结合成可溶性盐类的K+、Na+等离子[15]的浓度较大;氯离子浓度范围为12.07~52.97 mg/L,符合《地表水质量标准》(GB3838-2002)标准(小于250 mg/L)水质要求[16]。
3 结 论
比较了硝酸银滴定法、离子选择电极法和标准曲线法测定水中氯离子含量。选用标准加入法测定洛阳市区不同水样中氯离子含量,结论如下:
(1)离子选择电极标准加入法测定水中氯离子含量,操作简单,可行性强。
(2)自来水、回用中、地下水及地表水体中氯离子浓度范围分别为24.01~42.97 mg/L、22.37~47.55 mg/L、52.97~59.49 mg/L、12.07~52.97 mg/L,均符合相应的标准要求。
(3)地下水类中黄河口井水中氯离子浓度最高(59.49 mg/L),符合《地下水质量标准》Ⅱ类标准要求。从氯离子含量看,洛阳市水体质量良好。
参考文献
[1] GB 5749-2006 生活饮用水卫生标准[S].2006.
[2] Jakmunee J, Patimapornlert L, Suteerapataranon S, et al. Sequential injection with lab-at-valve (LAV) approach for potentiometric determination of chloride[J]. Talanta,2005,65(3):789-793.

本文发布于:2024-09-21 22:00:34,感谢您对本站的认可!

本文链接:https://www.17tex.com/xueshu/18354.html

版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。

标签:氯离子   标准   含量   水样   测定