黄陵县医院家属楼老旧小区基础设施配套
改造项目外墙保温
施
工
方
案
编 制 人:魏 守 强
审 核 人:何 华
审 批 人:陈 强
2020年4月17日
智能断句
1、工程概况 ···········································································3
2、材料性能及求······································································3 3、施工条件环境要求································································5
4、施工机械及工具 ··································································5
5、工艺流程 ···································································· 沥青阻尼板·········6
5.1 基层清理···························································· ·····7
5.2 吊顺直线······················································ ······7
5.3 配制粘接砂浆 ···························································7
5.4 排版 ······························································7
5.5 粘贴保温板····················································· ······7
5.6 大面积粘贴···································································· ·····8
5.7 施工要点·······························································9
5.8 特殊部位施工····································································10
5.9 锚固件施工工································································12
5.10 抹面层工··········································································15
5.11 质量制·············································································16
6 人力资管理···············································································16
7 安全生产保证措施 ······································································16
8文明施工及成品保护·································································18
1、工程概况
黄陵县医院家属楼老旧小区基础设施配套改造项目9、5、6、8#楼工程,工程地址位黄陵县医院家属楼老旧小区内,本工程高层楼体外墙采用玄武岩防火保温板(TEPS)为主要保温隔热材料,以粘、钉结合方式与墙身固定,抗裂砂浆复合耐碱玻纤网格布为保护增强层,涂料饰面的外墙保温系统。
2、材料性能及要求
2.1 保温材料
2.1.1 玄武岩防火保温板(TEPS)的性能除符合相关标准的规定外,还应符合表1的要求。
2.1.2玄武岩防火保温板(TEPS)的规格为 1200m数控卧式滚齿机m×600mm×4提拉下水5mm,平头式,阻燃型,其尺寸偏差应符合表2的要求。
2.2 粘接砂浆和抹面砂浆
粘接砂浆和抹面砂浆必须符合要求,并由出厂合格证及出厂检验报告。
玄武岩防火保温板(TEPS)技术性能指标 表1
检验项目 | 技术指标 |
表观密度,kg/m3 | 140.0 |
垂直于板面方向的抗拉强度,MPa | ≥0.10且破坏部位不得位于粘贴界面 |
尺寸稳定性(700C,48h),% | ≤0.3 |
导热系数,W/(m·K) | ≤0.045 |
压缩性能(形变10%),MPa | ≥0.10 |
燃烧性能 | 软件发布A2级 |
| |
保温板尺寸允许偏差 表2
检验项目 | 厚度 | 长度 | 宽度 | 对角线差 | 板边平直 | 板面平整度 |
≤50 | 聚氨酯浆料>50 |
允许偏差(mm) | +1.5 | +2.0 | +2.0 | ±1.0 | 3.0 | ±2.0 | 1.0 |
| | | | | | | |
2.3 专用聚合物粘结砂浆、抹面砂浆厂家已配制好,现场施工时加水用手持式电动搅拌机搅拌,重量比为水:聚合物砂浆等于 1:5,可操作时间不小于 2h。其中粘接砂浆和抹面砂浆性能指抹应符合要求。 2.4锚栓
金属螺钉应采用不锈钢或经过表面防锈处理的金属制成,塑料钉和带圆盘的塑料膨胀套管应采用聚酰胺、聚乙烯或聚丙烯制成,制作塑料钉和塑料套管的材料不得使用回收的再生材料。锚栓的有效锚固深度在混凝土墙中不小于25mm,在砌体墙中不小于50mm,塑料圆盘直径不小于50mm,单个锚栓抗拉承载力标准值不小于0.3KN,且应进行拉拔力现场试验。