摘要 目的:应用双波长比值光谱法测定盐酸普鲁卡因注射液含量,消除盐酸普鲁卡因降解 产物对氨基苯甲酸的干扰。方法:根据盐酸普鲁卡因和对氨基苯甲酸的比值光谱特征,选择226 nm和246 nm作为测定波长。结果:盐酸普鲁卡因在5~30 μg.ml-1,对氨基苯甲酸在0.25~ 16 μg.ml-1浓度范围内线性关系良好,样品测定结果与药典方法一致(P>0.0 5)。本法也可对对氨基苯甲酸进行定量。结论:本法操作简便,灵敏度高,重现性好,样品测定结果准确。 关键词 双波长比值光谱法;比值光谱;盐酸普鲁卡因;对氨基苯甲酸 分类号:R971+.2 文献标识码:A 文章编号:1001-5213(2000)07-0409-03 Determination of procaine hydrochloride injection by dual-wavelength ratio spec trometry Sun Zengxian,Tan Hengshan,Zhang Qianfen,et al (No.1 The First Hospital of Lianyungang,Jiangsu Lianyungang 222002) ABSTRACT OBJECTIVE:Dual-wavelength ratio spectrometry was used for determinatio n of procaine hydrochloride injection,which could eliminate the disturbance of t he degradation product,para-aminobenzoic acid.METHODS:According to the ratio spectrum of procaine hydrochlori de and para-aminobenzoic acid,226 nm and 246 nm were selected as the determinat ion wavelengthes.RESULTS:Good linear correlations lied in procaine hydrochloride (5~30 μg.ml-1) and para-aminobenzoic acid(0.25~16 μg.ml-1 ),and there was no difference between the determination of the method and pharma copeia method(P>0.05).CONCLUSIONS:The method is sample,sensitive,precise and accurate . KEY WORDS dual-wavelength ratio spectrometry;ratio spectrum;procaine hydrochloride;para- aminobenzoic acid 盐酸普鲁卡因注射液在生产和储存过程中易受pH和温度影响,水解产生对氨基苯甲酸(para -aminobenzoic acid,PABA),降低盐酸普鲁卡因(procaine hydrochloride,PCHC)的局麻作 用,同时也干扰PCHC的测定。中国药典[1]采用亚硝酸钠滴定法测定PCHC含量(测定 结果包含PABA含量)。有报道[2~4]采用系数倍率法、导数法、吸收度线性组合法 等方法测定PCHC含量,消除PABA干扰。本文采用双波长比值光谱法同时测定PCHC和PABA含量 ,具有操作简便快速、结果准确、灵敏度高、重现性好等特点。 1 仪器与试剂 岛津UV-260型紫外可见分光光度计;752-C型紫外可见分光光度计;PCHC符合中国药典199 5版规定;PABA由中国药品生物制品检定所提供;盐酸普鲁卡因注射液为市售;其他试剂均 为分析纯。 2 方法与结果 2.1标准储备液的配制 精密称取在105 ℃干燥至恒重的PCHC和PAB A各50 mg,分置100 ml量瓶中,各加适量pH 6.5磷酸缓冲液(BP)溶解并稀释至刻度,摇匀。 2.2 比值光谱绘制及测定波长选择 分别精密吸取PCHC和PABA标准储备 液适量,分置100 ml量瓶中,用BP稀释至刻度并摇匀。以BP作参比,在200~350 nm波长范 围内扫描,得到PCHC和PABA的吸收光谱,见1。计算波长λ处PCHC吸收度对PABA吸收度的 比值RPCHC,以RPCHC对λ作,得到PCHC的比值光谱;同样,也可以 得到PABA的比值光谱,见2。由2可知,PCHC在226 nm处有最大R值,在246 nm处有 最小R值;而PABA恰好与PCHC相反,在246 nm处有最大R值,226 nm处有最小R 值;故选择226 nm和246 nm作为PCHC和PABA的测定波长。 |
1 PCHC和PABA吸收光谱 |
2 PCHC和PABA比值光谱 2.3 标准曲线的绘制 分别精密吸取PCHC和PABA标准储备液适量,分置1 00 ml量瓶中,用BP稀释至刻度并摇匀,作为标准参比溶液(PCHC为10.1 μg.ml-1 ,PABA为3.0 μg.ml-1)。分别在226,246 nm处测定吸收度,PCHC分别为0 .271,0.077;PABA分别为0.081,0.155。 分别精密吸取PCHC和PABA标准储备液适量,分别用BP稀释至一定浓度,得到PCHC和PABA的系 列标准溶液,分别在226,246 nm处测定吸收度,计算ΔR,以浓度C对ΔR作线 性回归分析,得回归方程,见表1、表2。 表1 PCHC回归方程表2 PABA回归方程 |
C/μg.ml-1 | A226 | A246 | R226 | R246 | ΔR |
5.01 | 0.141 0 | 0.041 0 | 1.740 7 | 0.264 5 | 1.476 2 |
10.10 | 0.271 0 | 0.077 0 | 3.345 7 | 0.496 8 | 2.848 9 |
14.95 | 0.405 0 | 0.115 0 | 5.000 0 | 0.741 9 | 4.258 1 |
20.00 | 0.538 0 | 0.154 0 | 6.642 0 | 0.993 6 | 5.648 4 |
25.05 | 0.665 0 | 0.188 0 | 8.209 9 | 1.212 9 | 6.997 0 |
29.90 | 0.796 0 | 0.225 0 | 9.827 2 | 1.451 6 | 8.375 6 |
ΔR=0.277 2.C+0.082 7 r=0.999 9 | |||||
表2 PABA回归方程 |
C/μg.ml-1 | A226 | A246 | R226 | R246 | ΔR |
0.25 | 0.014 0 | 0.017 0 | 0.051 7 | 0.220 8 | 0.169 1 |
0.50 | 0. 0 | 0.029 5 | 0.073 8 | 0.383 1 | 0.309 3 |
1.00 | 0.033 0 | 0.055 0 | 0.121 8 | 0.714 3 | 0.592 5 |
2.00 | 0.057 0 | 0.106 0 | 0.210 3 | 1.376 6 | 1.166 3 |
4.00 | 0.109 0 | 0.208 0 | 0.402 2 | 2.701 3 | 2.299 1 |
8.01 | 0.210 5 | 0.407 0 | 0.776 8 | 5.285 7 | 4.508 9 |
16.02 | 0.412 0 | 0.801 0 | 1.520 3 | 10.402 6 | 8.882 3 |
ΔR=0.552 7.C+0.051 9 r=0.999 9 | |||||
2.4 回收率试验 精密吸取PCHC和PABA标准储备液适量,按处方比例加 入氯化钠,用BP稀释成含不同浓度的PCHC、PABA和含氯化钠均为6.25 μg.ml-1 的溶液,按上法测定,计算PCHC和PABA含量,结果见表3。 表3 回收率分析 |
编号 | PCH C/μg.ml-1 | PCBA/μg.ml-1 | ||
加入量 | 检出量 | 加入量 | 检出量 | |
1 | 20.00 | 20.33 | 0.80 | 0.81 |
2 | 22.62 | 23.23 | 0.50 | 0.50 |
3 | 25.05 | 25.14 | 0.30 | 0.29 |
4 | 27.47 | 27.42 | 0.25 | 0.25 |
5 | 29.90 | 29.67 | 0.16 | 0.18 |
平均回收率/% | 100.8 | 102.1 | ||
RSD/% | 1.40 | 5.95 | ||
2.5 样品测定 精密吸取样品2.5 ml,置100 ml量瓶中,加水稀释 至刻度并摇匀;精密吸取上液2.5 ml,置50 ml量瓶中,用BP稀释至刻度并摇匀(约含PC HC 25 μg.ml-1)。在226,246 nm处测吸收度,计算PCHC和PABA含量。并与中国药 典法(1995版)比较,结果见表4。 表4 本法与药典法测定盐酸普鲁卡因注射液含量结果 注:每支2 ml,含PCHC 40 mg。 |
编 号 | PCH C检出量(mg/支) | PABA检出量(mg/支) | ||
本 法 | 药典法 | 本 法 | 药典法 (限量0.48 mg) | |
1 | 38.16 | 38.00 | 0.32 | 合格 |
2 | 38.03 | 38.06 | 卤钨灯光谱0.27 | 合格 |
3 | 37.95 | 37.98 | 0.35 | 合格 |
4 | 38.56 | 38.79 | 0.42 | 合格 |
平均标示量/% | 95.4±0.7 | 95.5±1.0 | 0.89±0.16 | 药典限 量 1.2% |
3 讨论 介质的选择对PCHC测定有较大影响,因PCHC易受pH影响而水解,本文选择pH 6.5磷酸盐 缓冲液作为测定介质,一方面是为了增加PCHC的稳定性;一方面可消除PABA吸收峰移位。关 润华[4]报道PABA在水溶液中吸收峰随浓度增大而长移,而在pH 6.5的磷酸盐 缓冲液中吸收峰的位置不受浓度影响,并能提高测定的重现性和准确性。 用本法对PABA定量时,浓度越高测定结果越准确,重现性也越好,对接近或超过规定限度的 检品尤为适宜。 孙增先(连云港市第一人民医院,江苏 连云港 222002) 谈恒山(南京军区南京总医院,江苏 南京 210002) 张骞峰(连云港市第一人民医院,江苏 连云港 222002) 李恭润(连云港市第一人民医院,江苏 连云港 222002) 王奎兴(连云港市第一人民医院,江苏 连云港 222002) 李永溟(连云港市第一人民医院,江苏 连云港 222002) 参考文献 1,中国药典[S].二部,1995:713 2,孙金平,季瑛.倍增差示双波长分光光度法测定盐酸普鲁卡因注射液的含量[J] .现代应用药学杂志,1992,9(5):231 3,李毅然,李敬涵.一阶导数光谱法测定盐酸普鲁卡因注射液的含量[J].中国医 院药学杂志,1987,7(11):502 4,关润华.吸收度线性组合分光光度法测定盐酸普鲁卡因注射液含量[J].中国医 院药学杂志,1991,11(4):170 收稿日期:1999-04-30 |