EMC_Facility_report_图文


2023年12月16日发(作者:污污的段子让女生反应的话)

Example EMC Facilities Report

1/76

Acceptance of component or subsystem EMC test data requires the test laboratory to be

“recognized” by Ford Motor Company. This recognition process requires two distinct steps: They

are:

Accreditation to Ford Motor Company referenced test methods per the

Step 1:

Automotive EMC Laboratory Recognition Program (AEMCLRP). For

details about this program, go to /

Step 2:

Preparation and submittal of EMC Test Facility Report. Note that this is

only required if the laboratory seeks recognition to Ford component EMC

test methods delineated in ES-XW7T-1A278-AC and that are not covered

in the AEMCLRP scope of accreditation.

EMC Test Facilities Report

When the test facility report is received, reviewed and approved by Ford Motor Company, you will be

contacted via email verifying that Ford Motor Company has “recognized” your test facility. Note that

test facility reports will only be accepted after accreditation (Step 1) has been achieved.

The attached template shall be used when preparing the EMC Test Facilities Report. The report

shall be submitted, using a PDF format, to the individuals listed below.

Keith Frazier (kfrazie1@):

Test facilities located in North/South America and Asia

• Ayhan Gunsaya (agunsaya@):

Test facilities located in Europe

Questions concerning the test facility report should be forwarded to either Keith Frazier or Ayhan

Gunsaya.

Test Facility Report Template

1. Location of Test Services

Provide detail of the geographic location of the test facility.

2. Date of AEMCLRP Accreditation

Provide date of accreditation

3. Key Contact

Provide name, phone number, FAX, and email of the EMC test laboratory manager. Also provide

the name of the key contact for the facility if different than the laboratory manager.

4. Description of Test Equipment

List of test equipment used to support testing per Ford Motor Company test methods delineated in

ES-XW7T-1A278-AC. Provide latest calibration dates where applicable.

Not that the location of the test facility determines where the report shall be sent.

Example EMC Facilities Report

2/76

5. Generic Test Setup Description

Provide a description of the test setup used for performing each Ford component EMC test (see

Table below). The description shall include the following:

• Block diagrams of the test setup including list of actual equipment used (include

manufacture's name and model number)

• Dimensioned diagrams and photos to illustrate critical aspects of each test. Examples

include grounding locations, wire jig and load box details.

• Diagrams and/or photos illustrating how control and monitor signals are brought in and out of

the test chamber to support a typical component test.

• For immunity testing, provide measurements of actual test signals

List of Test Methods per ES-XW7T-1A278-AC

Test Designation

RI 112

RI 114

RI 130

RI 140

RI 150

CI 210

CI 220

CI 230

CI 250

CI 260

CI 270

CI 280

RE 310

CE 410

CE 420

Description

Radiated Immunity (1 – 400 MHz): Bulk Current Injection

Radiated Immunity (400 – 2000 MHz):

Reverberation Method

Absorber Lined Shielded Enclosure (ALSE) Method

Coupled Immunity (Inductive Transients)

Magnetic Field Immunity

Coupled Immunity (Charging System)

Immunity from Continuous Disturbances

Immunity from Transient Disturbances

Immunity from Power Cycling

Immunity from Voltage Offset

Immunity from Voltage Dropout

Immunity from Voltage Overstress

Immunity from Electrostatic Discharge (ESD)

Radiated Emissions

Conducted Transient Emissions

Conducted RF Emissions

The following pages serve an example of a well written test facility report.

Test facility report example courtesy of:

Denso Engineering Service Corporation &

Motorola Automotive Components and Electronics System Group

Example EMC Facilities Report

3/76

Prepared for Ford Motor Company

This report presents detailed information regarding XYZ EMC Testing Service's

capabilities to perform testing per test methods delineated in Ford EMC specification

ES-XW7T-1A278-ACXYZ EMC Testing Services

Test Facility Report

Example EMC Facilities Report

1. Location of Test services

Company

Address

TEL

FAX

: XYZ EMC Testing Services

: Automotive City, US

: 313-555-1212

: 313-555-1234

4/76

2. Date of AEMCLAP Accreditation: April 1, 2005 -xx

3. Key Contact

Contact Person:

John Doe

Manager: EMC Laboratory

TEL: 313-555-1214

FAX: 313-555-1215

e-mail: @XYZ_

Example EMC Facilities Report

5/76

4. Description of Test Equipment

RI112: RF Immunity, BCI

Calibration Procedure

Name

Injection Probe

Signal Generator

Power Amplifier

Power Amplifier

Power Meter

Power Sensor

Power Sensor

Dual Direction Coupler

Artificial Network (LISN)

Artificial Network (LISN)

Manufacturer

FCC

IFR

Amplifier Research

Amplifier Research

BOONTON

BOONTON

BOONTON

Werlatone

Schawarzbeck

Schawarzbeck

Model number

F-140A

2023

100A250M1

50W1000AM

9200C

952001B

952001B

C5081

NNBM8125

NNBM8125

Aug. 19, 2004

Aug. 19, 2004

Aug. 19, 2004

Oct. 4, 2004

Oct. 4, 2004

Oct. 4, 2004

Date

Oct. 4, 2004

Aug. 19, 2004

Intervals

1 year

1 year

N/A

N/A

1 year

1 year

1 year

1 year

1 year

1 year

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Facility

Independent-lab.

Independent-lab.

RI114: RF Immunity, ALSE (except for Radar pulse)

Calibration Procedure

Name

Antenna,

Double Rigid Guide

Antenna,Horn

Power Meter

Power Sensor

Power Sensor

Dual Direction Coupler

Dual Direction Coupler

Power Amplifier

Power Amplifier

Signal Generator

Artificial Network (LISN)

Artificial Network (LISN)

Manufacturer Model number

Date Intervals

N/A

N/A

Jul. 22, 2004

Jul. 22, 2004

Jul. 22, 2004

Oct. 4, 2004

Oct. 4, 2004

1 year

1 year

1 year

1 year

1 year

N/A

N/A

Dec. 3, 2004

Oct. 4, 2004

Oct. 4, 2004

1 year

1 year

1 year

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Facility

ETS

Amplifier Research

ROHDE&SCHWARZ

ROHDE&SCHWARZ

ROHDE&SCHWARZ

BONN

BONN

BONN

BONN

Agilent Technologies

Schwarzbeck

Schwarzbeck

3106

AT4002

NRVD

NRV-Z51

NRV-Z51

BDC0810-1500

BDC1040-30

BLWA2010-400

TWAL0103-250

E4422B

NNBM8125

NNBM8125

Example EMC Facilities Report

RI130 : Coupled Immunity, Inductive

6/76

Calibration Procedure

Name

Wiring Harness fixture

Normal Close Relay

Battery

Manufacturer

MEC SYSTEM

Potter & Bramfield

NIPPON DENCHI

Model number

PW-002

KUP-14A15-12

96D26R

Date Intervals

N/A

N/A

N/A

Facility

RI140: Magnetic Field Immunity

Calibration Procedure

Name

Radiating Loop

Function Generator

Shunt Resistor

Audio Amplifier

Digital Multimeter

Artificial Network (LISN)

Manufacturer

Solar

NF

Solar

PIONEER

Agilent

Schwarzbeck

Model number

9230-1

WF1943A

7144-1.0

M-10X

34401A

NNBM8125

Jul. 20, 2004

Jul. 8, 2004

Aug. 6, 2004

Aug. 18, 2004

Date Intervals

N/A

1 year

1 year

N/A

1 year

1 year

Independent-lab.

Independent-lab.

Independent-lab.

In-house

Facility

RI150: Coupled Immunity, Charging System

Calibration Procedure

Name

Wiring Harness fixture

Audio Power Amplifier

Function Generator

Shunt Resistor

Oscilloscope

Current Probe

Manufacturer

MEC SYSTEM

PIONEER

NF

Micro Wave Factory

Tektronix

Tektronix

Model number

PW-002

M-10X

WF1943A

MSR10

TDS744A

TCP202

Aug. 6, 2004

Aug. 18, 2004

Aug. 4, 2004

Aug. 4, 2004

Date Intervals

N/A

N/A

1 year

1 year

1 year

1 year

Independent-lab.

In-house

Independent-lab.

In-house

Facility

CI210: Immunity from Continuous Disturbances

Name

DC Power Amplifier

DC Power Amplifier

Signal Generator

NF

SCHAFFNER

SCHAFFNER

Manufacturer Model number

AS-161-30

NSG5273

System 5200 Sep. 14, 2004

Calibration Procedure

Date Intervals

N/A

N/A

1 year In-house

Facility

Example EMC Facilities Report

CI220: Immunity from Transient Disturbances

Name

DC Power Supply

Function Generator

Transient Generator

Signal Generator

Manufacturer

KIKUSUI

NF

DENSO EMCES

SCHAFFNER

7/76

Model number

PAD35-100L

WF1943A

CIT1

System 5000

Calibration Procedure

Date Intervals

N/A

Aug. 6, 2004

Aug. 19, 2004

Sep. 14, 2004

1 year

1 year

1 year

Independent-lab.

In-house

Independent-lab.

Facility

CI230: Immunity to

Power Cycling

Name

Signal Generator

(Included one DC Power

Amplifier)

DC Power Amplifier

DC Power Amplifier

DC Power Amplifier

Thermal Chamber

NF

NF

SCHAFFNER

ESPEC

AS-161-30

AS-161-30

NSG5273

PG-2KTH

N/A

N/A

N/A

N/A

SCHAFFNER System 5200 Sep. 14, 2004 1 year In-house

Manufacturer Model number

Calibration Procedure

Date Intervals Facility

CI250: Immunity to Voltage Offset

Name

Signal Generator

DC Power Amplifier

DC Power Amplifier

Manufacturer

SCHAFFNER

NF

SCHAFFNER

Model number

System 5200

AS-161-30

NSG5273

Calibration Procedure

Date

Aug. 6, 2004

Intervals

1 year

N/A

N/A

Facility

Independent-lab.

CI260: Immunity to Voltage Dropout

Name

Signal Generator

DC Power Amplifier

DC Power Amplifier

DC Power Amplifier

Normal Close Relay

Manufacturer

SCHAFFNER

NF

NF

SCHAFFNER

Potter & Brumfield

Model number

System 5200

AS-161-30

AS-161-30

NSG5273

KUP-14A15-12

Calibration Procedure

Date

Sep. 14, 2004

Intervals

1 year

N/A

N/A

N/A

N/A

Facility

In-house

Example EMC Facilities Report

CI270: Immunity to Voltage Overstress

Name

DC Power Supply

Manufacturer

KIKUSUI

8/76

Model number

PAD35-200LT *1

Calibration Procedure

Date Intervals

N/A

Facility

*1: Output Voltage 0 - 35 V, Output Current 0 - 200 A

CI280: Electro Static Discharge

Name

ESD Simulator

ESD Gun

Manufacturer

Noise Laboratory

Noise Laboratory

Model number

ESS-2000

TC-815P

Calibration Procedure

Date

Jul. 5, 2004

Jul. 5, 2004

Intervals

1 year

1 year

Facility

In-house

In-house

RE310: Radiated RF Emissions

Name

Antenna, Biconical

Antenna, Log-Periodic

Antenna, Monopole

Antenna, Horn

Artificial Network (LISN)

Artificial Network (LISN)

Spectrum Analyzer

EMI Test Receiver

Manufacturer

EMCO

EMCO

EMCO

EMCO

Schwarzbeck

Schwarzbeck

Agilent Technologies

ROHDE&SCHWARZ

Model number

3109

3146

3301B

3115

NNBM8125

NNBM8125

8546A

ESVS30

Calibration Procedure

Date

Sep. 25, 2004

Sep. 25, 2004

Sep. 25, 2004

AUG. 9, 2004

Oct.4, 2004

Oct. 4, 2004

Aug. 10, 2004

Aug. 12, 2004

Intervals

1 year

1 year

1 year

1 year

1 year

1 year

1 year

1 year

Facility

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

CE410: Conducted Transient Emissions

Name

Oscilloscope

Artificial Network (LISN)

Manufacturer

Tektronix

Schwarzbeck

Model number

TDS744A

NNBM8125

Calibration Procedure

Date

Aug. 4, 2004

Jul. 8, 2004

Intervals

1 year

1 year

Facility

Independent-lab.

Independent-lab.

CE420: Conducted RF Emissions

Name

Spectrum Analyzer

EMI Test Receiver

Artificial Network (LISN)

Artificial Network (LISN)

Manufacturer

Agilent Technologies

ROHDE&SCHWARZ

Schwarzbeck

Schwarzbeck

Agilent Technologies

Model number

8546A

ESVS30

NNBM8125

NNBM8125

8491A

Calibration Procedure

Date

Aug. 10, 2004

Aug. 12, 2004

Oct. 4, 2004

Oct. 4, 2004

Oct. 4, 2004

Intervals

1 year

1 year

1 year

1 year

1 year

Facility

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Independent-lab.

Attenuator

Example EMC Facilities Report

9/76

5. Generic Test Setup Description

RI 112: RF Immunity, BCI

Setup

Ground PlaneBattery+-LISNLISN750450Insulator150TestFixtureInjectionProbeDUT1700MonitorCameraCoaxialCableOpticalLinkInside of ALSEPower AmplifierSignal GeneratorFunctionGeneratorTVMonitorOscilloscope orDigital Multi MeterPower MeterPhotographs

LISN

Injection Probe

DUT

Test Fixture

Example EMC Facilities Report

10/76

Waveform (SG Output)

CW CW (Zoom In)

AM (1kHz, 80%)

Example EMC Facilities Report

Calibration data

11/76

Calibration Data 1-30 MHz

Band: 1 & 2

Frequency: 1-30MHz

Target current:: 70 -106 dBuA (1-15MHz) (Level2)

106 dBuA (15-30MHz) (Level2)

Date: August 17, 2004

Shielded room:

Probe:

Operator:

Forward power

[dB(mW)]

4.29

8.49

11.95

14.87

17.24

19.27

21.02

22.52

23.93

25.17

26.3

27.36

28.3

29.22

30.1

30.92

31.62

32.39

33

33.72

34.24

34.9

35.36

35.96

36.38

36.95

37.32

37.8

38.22

38.25

38.28

38.21

38.26

38.21

38.27

No.4

F-140A

Aihoshi

Frequency

[MHz]

1

1.5

2

2.5

3

3.5

4

4.5

5

5.5

6

6.5

7

7.5

8

8.5

9

9.5

10

10.5

11

11.5

12

12.5

13

13.5

14

14.5

15

15.5

16

16.5

17

17.5

18

Current

[dB(uA)]

70.08

75.51

79.22

82.23

84.62

86.67

88.48

90

91.41

92.68

93.83

94.93

95.87

96.8

97.69

98.51

99.22

100.01

100.63

101.37

101.9

102.56

103.04

103.66

104.1

104.7

105.09

105.56

106.01

106.05

106.08

106.02

106.08

106.02

106.09

Signal generator

[dB(mW)]

-50.4

-45.6

-42.2

-39.4

-37.1

-35.1

-33.5

-32.1

-30.8

-29.6

-28.4

-27.3

-26.3

-25.1

-24.2

-23.2

-22.5

-21.6

-21.3

-20.6

-20.1

-19.5

-19.1

-18.6

-18.2

-17.7

-17.3

-16.8

-16.3

-16.2

-16.1

-16.1

-16

-16

-15.9

Reflection power

[dB(mW)]

0.42

2.03

2.45

3.33

4.59

5.83

7.1

8.35

11.19

11.33

12.38

13.43

14.36

15.21

16.04

16.79

17.42

18

18.51

18.97

19.37

19.73

20.08

20.42

21.42

21.39

21.77

22.3

22.86

23.08

23.32

23.51

23.79

23.99

24.26

Example EMC Facilities Report

Frequency

[MHz]

18.5

19

19.5

20

20.5

21

21.5

22

22.5

23

23.5

24

24.5

25

25.5

26

26.5

27

27.5

28

28.5

29

29.5

30

Current

[dB(uA)]

106.05

106.03

106.04

106.07

106.1

106

106.03

106.05

106.06

106.06

106.07

106.04

106.09

106.04

106.07

106.1

106

106.03

106.06

106.01

106.08

106.08

106.1

106.09

12/76

Signal generator

[dB(mW)]

-15.9

-15.9

-15.9

-15.9

-15.9

-16.1

-16.1

-16.1

-16.1

-16.1

-16.1

-16.1

-16

-16

-15.9

-15.8

-15.8

-15.7

-15.6

-15.6

-15.5

-15.5

-15.5

-15.5

Forward power

[dB(mW)]

38.24

38.22

38.24

38.29

38.33

38.24

38.29

38.32

38.34

38.34

38.34

38.31

38.36

38.29

38.31

38.32

38.22

38.23

38.23

38.18

38.22

38.21

38.22

38.21

Reflection power

[dB(mW)]

24.4

24.47

24.61

24.72

24.79

24.68

24.67

24.61

24.51

24.32

24.13

23.89

23.7

23.44

23.27

23.14

22.94

22.93

23

23.09

23.32

23.55

23.82

24.09

Example EMC Facilities Report

Calibration Data 30-400 MHz

Band: 3

Frequency: 30-400 MHz

Target current:: 106 -95 dBuA (Level2)

Date: August 17, 2004

13/76

Shielded room:

Probe:

Operator:

No.4

F-140A

Aihoshi

Frequency

[MHz]

30

32

34

36

38

40

42

44

46

48

50

52

54

56

58

60

62

64

66

68

70

72

74

76

78

80

82

84

86

88

90

92

94

96

98

100

102

104

106

108

Current

[dB(uA)]

106.01

105.75

105.55

105.23

105.06

104.78

104.66

104.47

104.22

104.11

103.92

103.74

103.51

103.44

103.27

103.14

103.03

102.88

102.73

102.53

102.52

102.3

102.24

102.06

102.04

101.84

101.83

101.74

101.63

101.45

101.34

101.29

101.17

101.14

100.98

100.94

100.89

100.78

100.68

100.58

Signal generator Forward power Reflection power

[dB(mW)]

-15.5

-16.1

-16.1

-15.9

-15.9

-16.6

-16.8

-16.5

-16.4

-16.8

-17.2

-17.1

-17

-17.3

-17.9

-18

-17.9

-18.1

-18.4

-18.7

-18.7

-19

-19.1

-19.2

-19.2

-19.5

-19.5

-19.5

-19.7

-19.9

-19.7

-19.6

-19.9

-19.9

-19.8

-19.7

-17.9

-17.9

-17.8

-17.7

[dB(mW)]

38.12

37.86

37.72

37.42

37.24

36.91

36.74

36.54

36.36

36.33

36.2

36

35.7

35.56

35.39

35.31

35.25

35.15

35

34.71

34.62

34.42

34.5

34.36

34.39

34.18

34.09

33.95

33.84

33.76

33.73

33.71

33.56

33.5

33.36

33.46

33.57

33.66

33.73

33.68

[dB(mW)]

24.56

24.67

24.79

24.03

22.79

21.55

21.64

22.59

23.24

23.27

22.4

20.93

19.68

19.97

21.94

22.22

22.14

21.11

19.51

19.02

18.98

21.42

21.87

21.44

20.28

18.18

17.61

17.43

18.93

20.3

20.75

20.22

18.77

17.24

17.61

19.51

22.11

21.68

20.79

19.04

Example EMC Facilities Report

Frequency

[MHz]

110

112

114

116

118

120

122

124

126

128

130

132

134

136

138

140

142

144

146

148

150

152

154

156

158

160

162

164

166

168

170

172

174

176

178

180

182

184

186

188

190

192

194

196

198

Current

[dB(uA)]

100.49

100.45

100.44

100.36

100.28

100.12

100.04

99.99

100

99.93

99.8

99.81

99.66

99.68

99.52

99.54

99.5

99.34

99.28

99.24

99.23

99.13

99.06

99.09

98.98

98.9

98.93

98.81

98.74

98.71

98.65

98.6

98.61

98.56

98.47

98.48

98.43

98.4

98.29

98.21

98.27

98.12

98.2

98.03

98.02

14/76

Signal generator Forward power Reflection power

[dB(mW)]

-17.6

-17.5

-17.5

-17.4

-17.6

-17.3

-17.5

-17.7

-17.9

-17.9

-17.8

-17.8

-18

-17.9

-17.8

-17.9

-18.1

-18.3

-18.2

-18.1

-18.1

-18.4

-18.6

-18.5

-18.4

-18.4

-18.5

-18.8

-18.8

-18.8

-18.9

-19.1

-19.1

-19

-19

-19.1

-19.4

-19.5

-19.4

-19.3

-19.3

-19.7

-19.7

-19.7

-19.6

[dB(mW)]

33.63

33.74

33.87

34.02

33.62

33.81

33.56

33.3

33.13

33.06

33.17

33.06

32.78

32.7

32.63

32.5

32.54

32.34

32.28

32.13

32.05

31.92

31.9

32

31.95

31.9

31.91

31.78

31.78

31.79

31.77

31.76

31.72

31.65

31.56

31.59

31.63

31.66

31.57

31.5

31.56

31.41

31.59

31.57

31.56

[dB(mW)]

18.49

18.7

22.11

22.92

21.86

21.5

19.39

19.01

19.22

21.96

22.35

21.62

19.59

18.58

16.9

16.98

18.7

19.96

20

19.06

17.36

16.28

17.36

19.24

20.35

20.35

19.27

17.33

15.72

16.38

18.03

19.08

19.07

17.96

16.33

15.9

17.6

19.51

20.5

20.39

19.26

17.25

15.7

16.71

18.56

Example EMC Facilities Report

Frequency

[MHz]

200

205

210

215

220

225

230

235

240

245

250

255

260

265

270

275

280

285

290

295

300

305

310

315

320

325

330

335

340

345

350

355

360

365

370

375

380

385

390

395

400

Current

[dB(uA)]

98

97.92

97.75

97.73

97.62

97.54

97.36

97.28

97.26

97.17

97

96.92

96.85

96.84

96.77

96.62

96.59

96.48

96.46

96.3

96.3

96.17

96.09

96.02

95.95

95.98

95.84

95.84

95.79

95.74

95.66

95.52

95.47

95.49

95.42

95.36

95.22

95.24

95.11

95.06

95

15/76

Signal generator Forward power Reflection power

[dB(mW)]

-19.6

-19.6

-19.3

-18.9

-18.5

-18.3

-17.9

-17.3

-17.3

-16.5

-17.1

-16.6

-17.4

-17.3

-18.2

-17.8

-18.7

-18.1

-18.8

-18.5

-18.9

-18.6

-18.8

-18.2

-18.3

-18.2

-18.1

-18.4

-17.9

-18.4

-18.1

-18.9

-18.4

-19

-18.2

-19.1

-18.8

-19.6

-19.1

-19.5

-18.7

[dB(mW)]

31.56

31.55

31.71

31.88

32.03

32.33

32.58

33

33.34

33.4

33.68

33.56

33.52

33.38

32.89

32.79

32.6

32.24

32.44

32.04

31.94

31.94

31.65

31.84

31.77

31.36

31.46

31.49

31.37

31.75

31.38

31.06

31.35

31.22

31.49

31.63

31.02

31.14

31.08

31.03

31.51

[dB(mW)]

19.76

19.11

18.82

22.68

18.69

19.85

22.94

21.4

24.69

24.6

23.44

25.62

24.79

25.02

25.9

23.77

24.4

24.83

23.66

24.94

24.67

22.92

24.4

24.1

23.83

24.68

23.29

23.45

24.27

23.68

24.37

24.1

22.96

24.14

24.01

24

24.52

23.36

23.38

24.35

23.85

Example EMC Facilities Report

16/76

RI 114: RF Immunity, ALSE (except for Radar pulse)

Setup

Inside of ALSE

PowerAmplifierSignalGeneratorPower Meter30001000Ground PlaneSize: 3000 x 1000200Height: 900Antenna positionabove 1000 ulatorCoaxial cableFunctionGeneratorOscilloscope orDigital MultiMeterTestFixture1500Antenna Height: 1000LISNLISN1001000MonitorCamera + -BatteryTV MonitorOptical cable

Example EMC Facilities Report

Photographs

17/76

Example EMC Facilities Report

18/76

Waveform (SG Output)

CW CW (Zoom In)

AM (1kHz 80%)

PM (PRR=217Hz, PD=0.57ms)

0.57ms

217Hz

Example EMC Facilities Report

Calibration data

Calibration Data - 1

Band:

Frequency:

Target field strength:

Polarization:

19/76

4

400-800MHz

100V/m (Level2)

Horizontal

Frequency

[MHz]

400

410

420

430

440

450

460

470

480

490

500

510

520

530

540

550

560

570

580

590

600

610

620

630

640

650

660

670

680

690

700

710

720

730

740

750

760

770

780

790

800

Date:

Anechoic chamber:

Antenna:

Field probe ID:

Operator:

August 18, 2004

No.5

EMCO 3106

104772

Kondo

Field Strength Signal Generator Forward Power Reflection Power

[V/m]

100.3

101.3

100.8

100.2

100.9

100.7

100.4

101.3

100.8

100.1

101.3

100.3

100.8

100.1

101.1

100.9

101

100.6

100.6

101

100.1

100.5

100.4

100.1

100.8

100.8

101

100.2

101.1

100.5

100.5

101

100.8

100.6

101

100

100.9

100.3

100.9

100.4

100.5

[dB(mW)]

-23

-23.3

-23.6

-23.5

-23.2

-22.7

-22.1

-22

-23.1

-23.5

-24

-25.2

-26.8

-27.2

-26.9

-26.4

-26.1

-25.7

-24.8

-25.2

-26

-26

-24.9

-24.7

-26.1

-27.9

-30.1

-30.9

-31

-30.2

-29.5

-29.5

-29.1

-28.5

-28.1

-28.9

-29.4

-30.2

-30.6

-29.8

-29

[dB(mW)]

47.32

46.98

46.48

46.4

46.75

47.3

48.04

48.8

48.31

48.29

48.23

47.15

46.41

46.07

46

46.01

45.88

45.78

46.35

46.1

45.44

45.28

45.81

46.15

45.92

45.47

45.23

45.26

45.15

45.36

45.42

45.14

45.37

44.86

44.81

44.75

44.78

44.47

44.77

44.83

45.42

[dB(mW)]

18.2

27.98

26.12

17.39

32.49

34.1

34.68

35.51

32.35

30

29.1

31.33

27

26.26

20.84

26.85

29.26

23.75

32.5

32.73

32.51

23.84

25.16

26.39

25.55

25.57

27.88

30.34

24.14

29.01

22.07

25.03

27.57

15.48

28.98

23.74

28.72

22.82

29.86

26.34

31.08

Example EMC Facilities Report

Calibration Data - 2

Band:

Frequency:

Target field strength:

Polarization:

[MHz]

400

410

420

430

440

450

460

470

480

490

500

510

520

530

540

550

560

570

580

590

600

610

620

630

640

650

660

670

680

690

700

710

720

730

740

750

760

770

780

790

800

20/76

4

400-800MHz

100V/m (Level2)

Vertical

Field Strength

[V/m]

100.2

100.2

100.5

101

101

101.1

101

100.1

100.3

101.1

100.1

100.5

100.7

100.2

100.4

100.2

100.4

100.6

100.6

100.3

100

100.1

100.2

100.1

100.8

101.4

101

100.3

100

100.6

100.7

100.1

100.4

100.8

100.6

101

100.4

100.1

100.8

100.8

100.8

Date:

Anechoic chamber:

Antenna:

Field probe ID:

Operator:

Signal Generator

[dB(mW)]

-23.1

-23.7

-23.6

-23.4

-23.2

-23.2

-22.8

-23.3

-23.9

-24.5

-25.1

-26

-27.3

-27.7

-26.7

-25.3

-24.1

-23

-22.6

-23.2

-23.1

-23.1

-23.1

-23.7

-25.3

-26.9

-29.2

-30

-29.8

-28.5

-27.8

-28.1

-27.7

-27

-26.7

-27.9

-28.7

-29.1

-29.3

-28.5

-28

Forward Power

[dB(mW)]

47.14

46.52

46.4

46.51

46.76

46.73

47.33

47.5

47.39

47.29

47.08

46.42

45.76

45.65

46.26

47.13

47.86

48.51

48.63

48.19

48.42

48.25

47.67

47.14

46.79

46.44

46.12

46.17

46.38

47.15

47.1

46.56

46.77

46.31

46.28

45.84

45.56

45.56

46.13

46.25

46.4

August 18, 2004

No.5

EMCO 3106

104772

Kondo

Frequency Reflection Power

[dB(mW)]

25.7

25.41

18.08

18.86

33.38

31.95

32.09

33.7

32.49

27.74

27.83

27.72

22.32

27.65

25.75

27.32

30.52

26.49

34.81

34.85

35.37

26.91

28.01

29.73

28.31

22.91

26.62

30.98

26.34

31.21

24.25

26.35

29.11

19.65

30.36

24.91

28.07

20.01

30.31

29.68

33.57

Example EMC Facilities Report

Calibration Data - 3

Band:

Frequency:

Target field strength:

Polarization:

21/76

5

800-1000MHz

70V/m (Level2)

Horizontal

Date:

Anechoic chamber:

Antenna:

Field probe ID:

Operator:

November 2, 2004

No.5

EMCO 3106

104772

Suzuki

Frequency

[MHz]

800

810

820

830

840

850

860

870

880

890

900

910

920

930

940

950

960

970

980

990

1000

Field Strength

[V/m]

70.1

70.6

70.1

70.4

70

70.1

70.3

70.4

70

70.5

70.2

70.4

70.2

70

70.8

70.2

70.7

70.1

70.3

70.1

70

Signal Generator

[dB(mW)]

-32.3

-31.5

-31.5

-30.7

-30.9

-31.4

-30.7

-29.6

-29.5

-29.4

-30.1

-31

-30.6

-30.3

-28.9

-28.8

-28.3

-27.8

-29.2

-28.9

-26.3

Forward Power

[dB(mW)]

42.03

42.79

43.12

43.39

42.76

42.4

42.32

42.99

43.69

44.4

44.43

44.12

44.66

44.56

45.22

45.31

45.54

45.45

44.98

45.19

45.37

Reflection Power

[dB(mW)]

20.97

25.15

22.6

25.97

24.62

19.26

26.69

24.61

26.52

24.19

26.66

24.23

31.63

21.74

31.16

26.73

28.26

29.43

27.17

24.88

27.04

Example EMC Facilities Report

Calibration Data - 4

Band:

Frequency:

Target field strength:

Polarization:

22/76

5

800-1000MHz

70V/m (Level2)

Vertical

Date:

Anechoic chamber:

Antenna:

Field probe ID:

Operator:

November 2, 2004

No.5

EMCO 3106

104772

Suzuki

Frequency

[MHz]

800

810

820

830

840

850

860

870

880

890

900

910

920

930

940

950

960

970

980

990

1000

Field Strength

[V/m]

70.3

70.2

70.2

70.1

70.3

70.3

70.8

70

70.1

70

70.1

70.1

70.6

70.2

70

70.7

70.1

70.5

70.4

70.1

70.9

Signal Generator

[dB(mW)]

-31.3

-30.9

-30.9

-30.5

-29.7

-28.7

-28.5

-28.3

-28.7

-29

-28.8

-29.4

-29.3

-29.6

-29

-28.9

-28.6

-27.4

-29.1

-29.4

-26.9

Forward Power

[dB(mW)]

43.04

43.43

43.7

43.65

44.09

45.08

44.63

44.31

44.45

44.84

45.76

45.81

45.93

45.25

45.17

45.15

45.31

45.87

45.06

44.68

44.84

Reflection Power

[dB(mW)]

28.02

27.66

22.03

24.11

24.6

29.37

26.72

22.89

26.28

22.89

31.16

23.47

32.68

20.4

29.7

27.99

29.74

31.24

26.39

22.81

26.99

Example EMC Facilities Report

Calibration Data - 5

Band:

Frequency:

Target field strength:

Polarization:

23/76

5

1000-2000MHz

70V/m (Level2)

Horizontal

Field Strength

[V/m]

1000

1020

1040

1060

1080

1100

1120

1140

1160

1180

1200

1220

1240

1260

1280

1300

1320

1340

1360

1380

1400

1420

1440

1460

1480

1500

1520

1540

1560

1580

1600

1620

1640

1660

1680

1700

1720

70.8

70.8

70.1

70.7

70.9

70

70.6

70

70.6

70.6

70.1

70

70.8

70

70.8

70

70

70.6

70.6

70.7

70.1

70.2

70

70.2

70.7

70.6

70.1

70.3

70.7

70.6

70.1

70.1

70.1

70

70

70.1

70

Date:

Anechoic chamber:

Antenna:

Field probe ID:

Operator:

Forward Power

[dB(mW)]

40.79

40.44

40.64

40.28

39.67

39.16

39.21

39.36

39.35

39.37

39.21

39.03

38.62

38.1

37.78

37.42

37.18

36.91

36.61

36.89

37.3

36.42

36.7

35.78

36.45

36.7

36.44

35.89

36.26

36.6

35.97

35.51

35.56

35.21

34.81

34.48

34.29

December 1, 2004

No.5

AT4002

200030

Kondo

Frequency

[MHz]

Signal Generator

[dB(mW)]

-11.3

-11.3

-11

-11.6

-12.1

-12.4

-12.3

-12.1

-12.1

-11.7

-12

-12.3

-12.7

-13.1

-13.3

-13.8

-14.1

-14

-13.9

-13.7

-13.6

-14.4

-14

-14.8

-14

-13.6

-14

-14.4

-13.7

-13.1

-13.7

-14.3

-14.2

-14.6

-14.9

-15.2

-15.1

Reflection Power

[dB(mW)]

31.19

25.17

27.34

25.4

22.44

18.54

13.48

21.68

18.88

23.6

12.91

25.53

19.21

18.05

18.2

22.03

25.3

23.6

24.57

22.11

28.36

20.52

26.55

13.04

24.41

21.12

21.89

19.91

22.82

21.39

21.56

16.58

19.65

13.04

14.74

3.43

11.91

Example EMC Facilities Report

Frequency

[MHz]

1740

1760

1780

1800

1820

1840

1860

1880

1900

1920

1940

1960

1980

2000

Field Strength

[V/m]

70.7

70.9

70

70.9

70.4

70.8

70.1

70.1

70.7

70

70.7

70.2

70.8

70.3

24/76

Signal Generator

[dB(mW)]

-14.2

-14.5

-14.6

-14.4

-14.4

-14.1

-14.1

-14.8

-14.5

-14.4

-14.2

-14.7

-14.2

-13.4

Forward Power

[dB(mW)]

35.16

35.06

34.82

35.06

35.01

35.21

35.02

34.44

34.82

34.77

34.63

34.41

34.86

35.73

Reflection Power

[dB(mW)]

17.57

12.26

18.3

12.05

15.33

4.93

15.2

10.32

17.96

4.37

18.37

6.99

8.87

10.11

Example EMC Facilities Report

Calibration Data - 6

Band:

Frequency:

Target field strength:

Polarization:

25/76

5

1000-2000MHz

70V/m (Level2)

Vertical

Field Strength

[V/m]

1000

1020

1040

1060

1080

1100

1120

1140

1160

1180

1200

1220

1240

1260

1280

1300

1320

1340

1360

1380

1400

1420

1440

1460

1480

1500

1520

1540

1560

1580

1600

1620

1640

1660

1680

1700

1720

70.1

70.3

70.1

70.6

70.6

70.8

70.8

70.1

70.8

70.1

70

70.8

70.1

70.1

70.9

70

70.6

70.5

70.1

70.8

70.2

70

70.2

70.3

70.7

70.7

70

70.9

70

70.7

70.8

70.2

70.3

70.2

70.9

70

70.6

Signal Generator

[dB(mW)]

Date:

Anechoic chamber:

Antenna:

Field probe ID:

Operator:

Forward Power

[dB(mW)]

-9.7

-9.7

-9

-10.3

-11.1

-11.3

-10.7

-10.3

-10.9

-10

-9.6

-10.4

-11.4

-11.1

-11.4

-12

-12

-10.5

-9.9

-10.7

-11.5

-12

-11.6

-12.4

-11.6

-10.7

-11.3

-11

-10.5

-10.4

-9.9

-10.9

-11.9

-11.8

-11.4

-12

-11.4

42.38

42.12

42.56

41.54

40.77

40.26

40.79

41.1

40.54

41.09

41.64

41.03

40.03

40.25

39.77

39.11

39.22

40.36

40.64

39.93

39.49

38.94

39.1

38.14

38.83

39.65

39.2

39.35

39.49

39.25

39.8

38.92

37.87

38.06

38.34

37.67

38.01

December 1, 2004

No.5

AT4002

200030

Kondo

Frequency

[MHz]

Reflection Power

[dB(mW)]

32.67

27.05

29.26

27.54

22.04

17.93

19.27

19.77

19.88

25.33

19.25

26.78

19.7

19.18

22.02

22.98

26.47

26.73

29.68

25.85

30.22

21.96

28.6

17.78

26.91

22.96

23.83

23.98

26.51

24.25

24.42

19.16

21.32

18

20.56

7

12.27

Example EMC Facilities Report

Frequency

[MHz]

1740

1760

1780

1800

1820

1840

1860

1880

1900

1920

1940

1960

1980

2000

Field Strength

[V/m]

70.1

70

70.7

70.8

71

70.1

70.8

70.9

70

70

70

70.7

70.9

70.2

26/76

Signal Generator

[dB(mW)]

-11

-11.9

-11.5

-11.2

-11.2

-11.5

-11.1

-11

-10.5

-10.8

-10.6

-10.4

-10.6

-11.3

Forward Power

[dB(mW)]

38.34

37.65

37.97

38.3

38.25

37.89

38.14

38.32

38.86

38.37

38.22

38.79

38.42

37.95

Reflection Power

[dB(mW)]

19.7

17.36

20.85

13.17

19.92

8.15

17.67

14.05

23.53

13.53

20.41

10.41

13.1

12.41

Example EMC Facilities Report

RI 140: Magnetic field Immunity: Radiating Loop

27/76

Radiating LoopFunctionGenerator5cmDigitalMultimeterLISNAudioAmplifierDUTTestFixtureLISN+Battery-

Photographs

Function Generator Digital Multimeter Audio Amplifier

LISN Test Fixture

DUT

Shunt Resistor

Radiating Loop

Example EMC Facilities Report

Measured Magnetic Field Strength

28/76

Reading

Frequency Test Level

Target

Current

[ A ]

1.5647

0.3961

0.0350

0.0519

0.1055

0.5458

1.1080

Value of

Spectrum

Analyzer

[ Hz ]

50

100

340

500

1,000

5,000

10,000

[ dBpT ]

163.0

151.1

130.0

133.4

139.6

153.9

160.0

[ pT ]

141,253,754

35,756,792

3,162,039

4,689,128

9,519,064

49,271,087

100,021,712

[ dBuV ]

94.5

88.4

77.6

74.2

68.1

54.4

49.0

[ dB ]

69.2

63.4

53.0

59.7

71.9

99.8

111.5

Loop Sensor

Factor

Measured

Magnetic

Field

Strength *1

[ dBpT ]

163.7

151.8

130.6

133.9

140.0

154.2

160.5

*1: Measured Magnetic Field Strength = Reading Value of Spectrum Analyzer + Loop Sensor Factor

Example EMC Facilities Report

RI 130: Coupled Immunity, Inductive

29/76

Setup

TestFixtureWire Harness Fixture ConstructionCross SectionN/C RelayPowerSupply0.56Relay Wire10002000Insulator500Ground PlaneInsulatorDUTGround PlaneWiring HarnessRelay Wire, Wiring Harness: Bare copper wire

RI 150: Coupled Immunity, Charging System

Setup

TestFixtureCurrent ProbeWire Harness Fixture ConstructionCross Section10ohms10002000Oscilloscope6Charging WireAudioAmplifierFunctionGenerator5000.550Ground PlaneDUTGround PlaneWiring HarnessCharging Wire, Wiring Harness: Bare copper wire

50

Example EMC Facilities Report

30/76

Photographs

Wiring Harness Fixture

100 mm of separation

Test Fixture

DUT

DC Power Supply

Twisted Wire

Shielded Wire

NC Relay

Battery

Audio Amp.

Oscilloscope Current Probe

Function Generator

10 ohms

Example EMC Facilities Report

P & B Relay

31/76

Current Probe

Example EMC Facilities Report

Waveform

RI130

RI150

mA/mV

600 Hz

mA/mV

5,000 Hz

32/76

mA/mV

1,000 Hz

mA/mV

10,000 Hz

Example EMC Facilities Report

CI 210: Immunity from Continuous Disturbance

33/76

Setup

0 ohm Resistor for Level 10.25 ohms Resistor for Level 2DUT and wiring harnessare nal GeneratorDCPowerAmplifier

Photographs

Ground PlaneSystem 5200 Test Fixture

DC Power Supply

DC Power

Amplifier

0.25 ohms

Example EMC Facilities Report

Waveform

Level 1

50Hz

600Hz

10KHz

34/76

100Hz

1KHz

Example EMC Facilities Report

Level 2

50Hz

600Hz

10KHz

35/76

100Hz

1KHz

Example EMC Facilities Report

CI 220: Immunity from Transient Disturbance

36/76

Setup

CI220 Pulse A1 - CDC PowerSupplyTransientGeneratorDUTDUT and wiring harnessare PlaneCI220 Pulse D - EDC PowerSupplySignalGeneratorDUTDUT and wiring harnessare PlaneCI220 Pulse GDC PowerSupplySignalGenerator0.7 ohmsDUT and wiring harnessare und Plane

DUT

100 mH

Relay

Example EMC Facilities Report

37/76

D, E, F

DUT

DC Power Supply

G

DUT

DC Power Supply

Example EMC Facilities Report

Waveform

Pulse A1

Pulse A2

Pulse B1

Pulse C

38/76

Pulse A1

Pulse A2

Pulse B2

Example EMC Facilities Report

Pulse D Us

Pulse E Us

Pulse F Us

Pulse G Us

39/76

Pulse D tr

Pulse E tr

Pulse F tr

Pulse G tr

Example EMC Facilities Report

CI 230: Immunity to Power Cycling

40/76

Example EMC Facilities Report

Waveforms

41/76

Waveform A Verification (overall) Waveform B Verification (overall)

Waveform B Verification (intial)

Example EMC Facilities Report

42/76

Waveform C Verification (overall)

Waveform D Verification (overall)

Waveform C Verification (initial)

Waveform D Verification (initial)

Waveform C Verification (end) Waveform D Verification (end)

Example EMC Facilities Report

43/76

Waveform A, B, C, D Verification (overall) Waveform A, B, C, D Verification (intial)

Waveform A, B, C, D Verification (initial)

Waveform A, B Verification (initial)

Waveform A, B, C, D Verification (end)

Example EMC Facilities Report

CI 250: Immunity to Voltage Offset

44/76

Setup

Ground Offset of DUTSignalGeneratorDCAmplifierDUTPowerSupply+-TestFixtureGround PlaneInsulatorGround Offset of Sensor, Module or LoadSignalGeneratorDCAmplifierSensor, Moduleor LoadDUTPowerSupply+-TestFixtureGround PlaneInsulator

Photographs

DUT Ground

Waveform

Example EMC Facilities Report

CI 260: Immunity to Voltage Dropout

45/76

Setup

CI260-A, B & CSignal GeneratorDCPowerAmplifier2 ohmsDUTDUT and wiring harnessare PlaneCI260 - D & ESignal GeneratorDCPowerAmplifierDUTDUT and wiring harnessare PlaneCI260 - FSignalGeneratorDCPowerAmplifier1N/C RelayDUT and wiring harnessare GeneratorDCPowerAmplifier2DUTGround PlaneDCUpAmplifier 1DCUpAmplifier 2T2T3T1T1T2T4Up = 13.5 voltsT1 = 5 secT2 = 100 msecT3 = 2.5 secT4 = 7.4 sec

Example EMC Facilities Report

46/76

Example EMC Facilities Report

Waveform

47/76

Example EMC Facilities Report

CI260-A – 5V

48/76

50ms

Example EMC Facilities Report

49/76


本文发布于:2024-09-21 22:41:17,感谢您对本站的认可!