Example EMC Facilities Report
1/76
Acceptance of component or subsystem EMC test data requires the test laboratory to be
“recognized” by Ford Motor Company. This recognition process requires two distinct steps: They
are:
Accreditation to Ford Motor Company referenced test methods per the
Step 1:
Automotive EMC Laboratory Recognition Program (AEMCLRP). For
details about this program, go to /
Step 2:
Preparation and submittal of EMC Test Facility Report. Note that this is
only required if the laboratory seeks recognition to Ford component EMC
test methods delineated in ES-XW7T-1A278-AC and that are not covered
in the AEMCLRP scope of accreditation.
EMC Test Facilities Report
When the test facility report is received, reviewed and approved by Ford Motor Company, you will be
contacted via email verifying that Ford Motor Company has “recognized” your test facility. Note that
test facility reports will only be accepted after accreditation (Step 1) has been achieved.
The attached template shall be used when preparing the EMC Test Facilities Report. The report
shall be submitted, using a PDF format, to the individuals listed below.
•
Keith Frazier (kfrazie1@):
Test facilities located in North/South America and Asia
• Ayhan Gunsaya (agunsaya@):
Test facilities located in Europe
Questions concerning the test facility report should be forwarded to either Keith Frazier or Ayhan
Gunsaya.
Test Facility Report Template
1. Location of Test Services
Provide detail of the geographic location of the test facility.
2. Date of AEMCLRP Accreditation
Provide date of accreditation
3. Key Contact
Provide name, phone number, FAX, and email of the EMC test laboratory manager. Also provide
the name of the key contact for the facility if different than the laboratory manager.
4. Description of Test Equipment
List of test equipment used to support testing per Ford Motor Company test methods delineated in
ES-XW7T-1A278-AC. Provide latest calibration dates where applicable.
Not that the location of the test facility determines where the report shall be sent.
Example EMC Facilities Report
2/76
5. Generic Test Setup Description
Provide a description of the test setup used for performing each Ford component EMC test (see
Table below). The description shall include the following:
• Block diagrams of the test setup including list of actual equipment used (include
manufacture's name and model number)
• Dimensioned diagrams and photos to illustrate critical aspects of each test. Examples
include grounding locations, wire jig and load box details.
• Diagrams and/or photos illustrating how control and monitor signals are brought in and out of
the test chamber to support a typical component test.
• For immunity testing, provide measurements of actual test signals
List of Test Methods per ES-XW7T-1A278-AC
Test Designation
RI 112
RI 114
RI 130
RI 140
RI 150
CI 210
CI 220
CI 230
CI 250
CI 260
CI 270
CI 280
RE 310
CE 410
CE 420
Description
Radiated Immunity (1 – 400 MHz): Bulk Current Injection
Radiated Immunity (400 – 2000 MHz):
Reverberation Method
Absorber Lined Shielded Enclosure (ALSE) Method
Coupled Immunity (Inductive Transients)
Magnetic Field Immunity
Coupled Immunity (Charging System)
Immunity from Continuous Disturbances
Immunity from Transient Disturbances
Immunity from Power Cycling
Immunity from Voltage Offset
Immunity from Voltage Dropout
Immunity from Voltage Overstress
Immunity from Electrostatic Discharge (ESD)
Radiated Emissions
Conducted Transient Emissions
Conducted RF Emissions
The following pages serve an example of a well written test facility report.
Test facility report example courtesy of:
Denso Engineering Service Corporation &
Motorola Automotive Components and Electronics System Group
Example EMC Facilities Report
3/76
Prepared for Ford Motor Company
This report presents detailed information regarding XYZ EMC Testing Service's
capabilities to perform testing per test methods delineated in Ford EMC specification
ES-XW7T-1A278-ACXYZ EMC Testing Services
Test Facility Report
Example EMC Facilities Report
1. Location of Test services
Company
Address
TEL
FAX
: XYZ EMC Testing Services
: Automotive City, US
: 313-555-1212
: 313-555-1234
4/76
2. Date of AEMCLAP Accreditation: April 1, 2005 -xx
3. Key Contact
Contact Person:
John Doe
Manager: EMC Laboratory
TEL: 313-555-1214
FAX: 313-555-1215
e-mail: @XYZ_
Example EMC Facilities Report
5/76
4. Description of Test Equipment
RI112: RF Immunity, BCI
Calibration Procedure
Name
Injection Probe
Signal Generator
Power Amplifier
Power Amplifier
Power Meter
Power Sensor
Power Sensor
Dual Direction Coupler
Artificial Network (LISN)
Artificial Network (LISN)
Manufacturer
FCC
IFR
Amplifier Research
Amplifier Research
BOONTON
BOONTON
BOONTON
Werlatone
Schawarzbeck
Schawarzbeck
Model number
F-140A
2023
100A250M1
50W1000AM
9200C
952001B
952001B
C5081
NNBM8125
NNBM8125
Aug. 19, 2004
Aug. 19, 2004
Aug. 19, 2004
Oct. 4, 2004
Oct. 4, 2004
Oct. 4, 2004
Date
Oct. 4, 2004
Aug. 19, 2004
Intervals
1 year
1 year
N/A
N/A
1 year
1 year
1 year
1 year
1 year
1 year
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Facility
Independent-lab.
Independent-lab.
RI114: RF Immunity, ALSE (except for Radar pulse)
Calibration Procedure
Name
Antenna,
Double Rigid Guide
Antenna,Horn
Power Meter
Power Sensor
Power Sensor
Dual Direction Coupler
Dual Direction Coupler
Power Amplifier
Power Amplifier
Signal Generator
Artificial Network (LISN)
Artificial Network (LISN)
Manufacturer Model number
Date Intervals
N/A
N/A
Jul. 22, 2004
Jul. 22, 2004
Jul. 22, 2004
Oct. 4, 2004
Oct. 4, 2004
1 year
1 year
1 year
1 year
1 year
N/A
N/A
Dec. 3, 2004
Oct. 4, 2004
Oct. 4, 2004
1 year
1 year
1 year
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Facility
ETS
Amplifier Research
ROHDE&SCHWARZ
ROHDE&SCHWARZ
ROHDE&SCHWARZ
BONN
BONN
BONN
BONN
Agilent Technologies
Schwarzbeck
Schwarzbeck
3106
AT4002
NRVD
NRV-Z51
NRV-Z51
BDC0810-1500
BDC1040-30
BLWA2010-400
TWAL0103-250
E4422B
NNBM8125
NNBM8125
Example EMC Facilities Report
RI130 : Coupled Immunity, Inductive
6/76
Calibration Procedure
Name
Wiring Harness fixture
Normal Close Relay
Battery
Manufacturer
MEC SYSTEM
Potter & Bramfield
NIPPON DENCHI
Model number
PW-002
KUP-14A15-12
96D26R
Date Intervals
N/A
N/A
N/A
Facility
RI140: Magnetic Field Immunity
Calibration Procedure
Name
Radiating Loop
Function Generator
Shunt Resistor
Audio Amplifier
Digital Multimeter
Artificial Network (LISN)
Manufacturer
Solar
NF
Solar
PIONEER
Agilent
Schwarzbeck
Model number
9230-1
WF1943A
7144-1.0
M-10X
34401A
NNBM8125
Jul. 20, 2004
Jul. 8, 2004
Aug. 6, 2004
Aug. 18, 2004
Date Intervals
N/A
1 year
1 year
N/A
1 year
1 year
Independent-lab.
Independent-lab.
Independent-lab.
In-house
Facility
RI150: Coupled Immunity, Charging System
Calibration Procedure
Name
Wiring Harness fixture
Audio Power Amplifier
Function Generator
Shunt Resistor
Oscilloscope
Current Probe
Manufacturer
MEC SYSTEM
PIONEER
NF
Micro Wave Factory
Tektronix
Tektronix
Model number
PW-002
M-10X
WF1943A
MSR10
TDS744A
TCP202
Aug. 6, 2004
Aug. 18, 2004
Aug. 4, 2004
Aug. 4, 2004
Date Intervals
N/A
N/A
1 year
1 year
1 year
1 year
Independent-lab.
In-house
Independent-lab.
In-house
Facility
CI210: Immunity from Continuous Disturbances
Name
DC Power Amplifier
DC Power Amplifier
Signal Generator
NF
SCHAFFNER
SCHAFFNER
Manufacturer Model number
AS-161-30
NSG5273
System 5200 Sep. 14, 2004
Calibration Procedure
Date Intervals
N/A
N/A
1 year In-house
Facility
Example EMC Facilities Report
CI220: Immunity from Transient Disturbances
Name
DC Power Supply
Function Generator
Transient Generator
Signal Generator
Manufacturer
KIKUSUI
NF
DENSO EMCES
SCHAFFNER
7/76
Model number
PAD35-100L
WF1943A
CIT1
System 5000
Calibration Procedure
Date Intervals
N/A
Aug. 6, 2004
Aug. 19, 2004
Sep. 14, 2004
1 year
1 year
1 year
Independent-lab.
In-house
Independent-lab.
Facility
CI230: Immunity to
Power Cycling
Name
Signal Generator
(Included one DC Power
Amplifier)
DC Power Amplifier
DC Power Amplifier
DC Power Amplifier
Thermal Chamber
NF
NF
SCHAFFNER
ESPEC
AS-161-30
AS-161-30
NSG5273
PG-2KTH
N/A
N/A
N/A
N/A
SCHAFFNER System 5200 Sep. 14, 2004 1 year In-house
Manufacturer Model number
Calibration Procedure
Date Intervals Facility
CI250: Immunity to Voltage Offset
Name
Signal Generator
DC Power Amplifier
DC Power Amplifier
Manufacturer
SCHAFFNER
NF
SCHAFFNER
Model number
System 5200
AS-161-30
NSG5273
Calibration Procedure
Date
Aug. 6, 2004
Intervals
1 year
N/A
N/A
Facility
Independent-lab.
CI260: Immunity to Voltage Dropout
Name
Signal Generator
DC Power Amplifier
DC Power Amplifier
DC Power Amplifier
Normal Close Relay
Manufacturer
SCHAFFNER
NF
NF
SCHAFFNER
Potter & Brumfield
Model number
System 5200
AS-161-30
AS-161-30
NSG5273
KUP-14A15-12
Calibration Procedure
Date
Sep. 14, 2004
Intervals
1 year
N/A
N/A
N/A
N/A
Facility
In-house
Example EMC Facilities Report
CI270: Immunity to Voltage Overstress
Name
DC Power Supply
Manufacturer
KIKUSUI
8/76
Model number
PAD35-200LT *1
Calibration Procedure
Date Intervals
N/A
Facility
*1: Output Voltage 0 - 35 V, Output Current 0 - 200 A
CI280: Electro Static Discharge
Name
ESD Simulator
ESD Gun
Manufacturer
Noise Laboratory
Noise Laboratory
Model number
ESS-2000
TC-815P
Calibration Procedure
Date
Jul. 5, 2004
Jul. 5, 2004
Intervals
1 year
1 year
Facility
In-house
In-house
RE310: Radiated RF Emissions
Name
Antenna, Biconical
Antenna, Log-Periodic
Antenna, Monopole
Antenna, Horn
Artificial Network (LISN)
Artificial Network (LISN)
Spectrum Analyzer
EMI Test Receiver
Manufacturer
EMCO
EMCO
EMCO
EMCO
Schwarzbeck
Schwarzbeck
Agilent Technologies
ROHDE&SCHWARZ
Model number
3109
3146
3301B
3115
NNBM8125
NNBM8125
8546A
ESVS30
Calibration Procedure
Date
Sep. 25, 2004
Sep. 25, 2004
Sep. 25, 2004
AUG. 9, 2004
Oct.4, 2004
Oct. 4, 2004
Aug. 10, 2004
Aug. 12, 2004
Intervals
1 year
1 year
1 year
1 year
1 year
1 year
1 year
1 year
Facility
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
CE410: Conducted Transient Emissions
Name
Oscilloscope
Artificial Network (LISN)
Manufacturer
Tektronix
Schwarzbeck
Model number
TDS744A
NNBM8125
Calibration Procedure
Date
Aug. 4, 2004
Jul. 8, 2004
Intervals
1 year
1 year
Facility
Independent-lab.
Independent-lab.
CE420: Conducted RF Emissions
Name
Spectrum Analyzer
EMI Test Receiver
Artificial Network (LISN)
Artificial Network (LISN)
Manufacturer
Agilent Technologies
ROHDE&SCHWARZ
Schwarzbeck
Schwarzbeck
Agilent Technologies
Model number
8546A
ESVS30
NNBM8125
NNBM8125
8491A
Calibration Procedure
Date
Aug. 10, 2004
Aug. 12, 2004
Oct. 4, 2004
Oct. 4, 2004
Oct. 4, 2004
Intervals
1 year
1 year
1 year
1 year
1 year
Facility
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Independent-lab.
Attenuator
Example EMC Facilities Report
9/76
5. Generic Test Setup Description
RI 112: RF Immunity, BCI
Setup
Ground PlaneBattery+-LISNLISN750450Insulator150TestFixtureInjectionProbeDUT1700MonitorCameraCoaxialCableOpticalLinkInside of ALSEPower AmplifierSignal GeneratorFunctionGeneratorTVMonitorOscilloscope orDigital Multi MeterPower MeterPhotographs
LISN
Injection Probe
DUT
Test Fixture
Example EMC Facilities Report
10/76
Waveform (SG Output)
CW CW (Zoom In)
AM (1kHz, 80%)
Example EMC Facilities Report
Calibration data
11/76
Calibration Data 1-30 MHz
Band: 1 & 2
Frequency: 1-30MHz
Target current:: 70 -106 dBuA (1-15MHz) (Level2)
106 dBuA (15-30MHz) (Level2)
Date: August 17, 2004
Shielded room:
Probe:
Operator:
Forward power
[dB(mW)]
4.29
8.49
11.95
14.87
17.24
19.27
21.02
22.52
23.93
25.17
26.3
27.36
28.3
29.22
30.1
30.92
31.62
32.39
33
33.72
34.24
34.9
35.36
35.96
36.38
36.95
37.32
37.8
38.22
38.25
38.28
38.21
38.26
38.21
38.27
No.4
F-140A
Aihoshi
Frequency
[MHz]
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6
6.5
7
7.5
8
8.5
9
9.5
10
10.5
11
11.5
12
12.5
13
13.5
14
14.5
15
15.5
16
16.5
17
17.5
18
Current
[dB(uA)]
70.08
75.51
79.22
82.23
84.62
86.67
88.48
90
91.41
92.68
93.83
94.93
95.87
96.8
97.69
98.51
99.22
100.01
100.63
101.37
101.9
102.56
103.04
103.66
104.1
104.7
105.09
105.56
106.01
106.05
106.08
106.02
106.08
106.02
106.09
Signal generator
[dB(mW)]
-50.4
-45.6
-42.2
-39.4
-37.1
-35.1
-33.5
-32.1
-30.8
-29.6
-28.4
-27.3
-26.3
-25.1
-24.2
-23.2
-22.5
-21.6
-21.3
-20.6
-20.1
-19.5
-19.1
-18.6
-18.2
-17.7
-17.3
-16.8
-16.3
-16.2
-16.1
-16.1
-16
-16
-15.9
Reflection power
[dB(mW)]
0.42
2.03
2.45
3.33
4.59
5.83
7.1
8.35
11.19
11.33
12.38
13.43
14.36
15.21
16.04
16.79
17.42
18
18.51
18.97
19.37
19.73
20.08
20.42
21.42
21.39
21.77
22.3
22.86
23.08
23.32
23.51
23.79
23.99
24.26
Example EMC Facilities Report
Frequency
[MHz]
18.5
19
19.5
20
20.5
21
21.5
22
22.5
23
23.5
24
24.5
25
25.5
26
26.5
27
27.5
28
28.5
29
29.5
30
Current
[dB(uA)]
106.05
106.03
106.04
106.07
106.1
106
106.03
106.05
106.06
106.06
106.07
106.04
106.09
106.04
106.07
106.1
106
106.03
106.06
106.01
106.08
106.08
106.1
106.09
12/76
Signal generator
[dB(mW)]
-15.9
-15.9
-15.9
-15.9
-15.9
-16.1
-16.1
-16.1
-16.1
-16.1
-16.1
-16.1
-16
-16
-15.9
-15.8
-15.8
-15.7
-15.6
-15.6
-15.5
-15.5
-15.5
-15.5
Forward power
[dB(mW)]
38.24
38.22
38.24
38.29
38.33
38.24
38.29
38.32
38.34
38.34
38.34
38.31
38.36
38.29
38.31
38.32
38.22
38.23
38.23
38.18
38.22
38.21
38.22
38.21
Reflection power
[dB(mW)]
24.4
24.47
24.61
24.72
24.79
24.68
24.67
24.61
24.51
24.32
24.13
23.89
23.7
23.44
23.27
23.14
22.94
22.93
23
23.09
23.32
23.55
23.82
24.09
Example EMC Facilities Report
Calibration Data 30-400 MHz
Band: 3
Frequency: 30-400 MHz
Target current:: 106 -95 dBuA (Level2)
Date: August 17, 2004
13/76
Shielded room:
Probe:
Operator:
No.4
F-140A
Aihoshi
Frequency
[MHz]
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
66
68
70
72
74
76
78
80
82
84
86
88
90
92
94
96
98
100
102
104
106
108
Current
[dB(uA)]
106.01
105.75
105.55
105.23
105.06
104.78
104.66
104.47
104.22
104.11
103.92
103.74
103.51
103.44
103.27
103.14
103.03
102.88
102.73
102.53
102.52
102.3
102.24
102.06
102.04
101.84
101.83
101.74
101.63
101.45
101.34
101.29
101.17
101.14
100.98
100.94
100.89
100.78
100.68
100.58
Signal generator Forward power Reflection power
[dB(mW)]
-15.5
-16.1
-16.1
-15.9
-15.9
-16.6
-16.8
-16.5
-16.4
-16.8
-17.2
-17.1
-17
-17.3
-17.9
-18
-17.9
-18.1
-18.4
-18.7
-18.7
-19
-19.1
-19.2
-19.2
-19.5
-19.5
-19.5
-19.7
-19.9
-19.7
-19.6
-19.9
-19.9
-19.8
-19.7
-17.9
-17.9
-17.8
-17.7
[dB(mW)]
38.12
37.86
37.72
37.42
37.24
36.91
36.74
36.54
36.36
36.33
36.2
36
35.7
35.56
35.39
35.31
35.25
35.15
35
34.71
34.62
34.42
34.5
34.36
34.39
34.18
34.09
33.95
33.84
33.76
33.73
33.71
33.56
33.5
33.36
33.46
33.57
33.66
33.73
33.68
[dB(mW)]
24.56
24.67
24.79
24.03
22.79
21.55
21.64
22.59
23.24
23.27
22.4
20.93
19.68
19.97
21.94
22.22
22.14
21.11
19.51
19.02
18.98
21.42
21.87
21.44
20.28
18.18
17.61
17.43
18.93
20.3
20.75
20.22
18.77
17.24
17.61
19.51
22.11
21.68
20.79
19.04
Example EMC Facilities Report
Frequency
[MHz]
110
112
114
116
118
120
122
124
126
128
130
132
134
136
138
140
142
144
146
148
150
152
154
156
158
160
162
164
166
168
170
172
174
176
178
180
182
184
186
188
190
192
194
196
198
Current
[dB(uA)]
100.49
100.45
100.44
100.36
100.28
100.12
100.04
99.99
100
99.93
99.8
99.81
99.66
99.68
99.52
99.54
99.5
99.34
99.28
99.24
99.23
99.13
99.06
99.09
98.98
98.9
98.93
98.81
98.74
98.71
98.65
98.6
98.61
98.56
98.47
98.48
98.43
98.4
98.29
98.21
98.27
98.12
98.2
98.03
98.02
14/76
Signal generator Forward power Reflection power
[dB(mW)]
-17.6
-17.5
-17.5
-17.4
-17.6
-17.3
-17.5
-17.7
-17.9
-17.9
-17.8
-17.8
-18
-17.9
-17.8
-17.9
-18.1
-18.3
-18.2
-18.1
-18.1
-18.4
-18.6
-18.5
-18.4
-18.4
-18.5
-18.8
-18.8
-18.8
-18.9
-19.1
-19.1
-19
-19
-19.1
-19.4
-19.5
-19.4
-19.3
-19.3
-19.7
-19.7
-19.7
-19.6
[dB(mW)]
33.63
33.74
33.87
34.02
33.62
33.81
33.56
33.3
33.13
33.06
33.17
33.06
32.78
32.7
32.63
32.5
32.54
32.34
32.28
32.13
32.05
31.92
31.9
32
31.95
31.9
31.91
31.78
31.78
31.79
31.77
31.76
31.72
31.65
31.56
31.59
31.63
31.66
31.57
31.5
31.56
31.41
31.59
31.57
31.56
[dB(mW)]
18.49
18.7
22.11
22.92
21.86
21.5
19.39
19.01
19.22
21.96
22.35
21.62
19.59
18.58
16.9
16.98
18.7
19.96
20
19.06
17.36
16.28
17.36
19.24
20.35
20.35
19.27
17.33
15.72
16.38
18.03
19.08
19.07
17.96
16.33
15.9
17.6
19.51
20.5
20.39
19.26
17.25
15.7
16.71
18.56
Example EMC Facilities Report
Frequency
[MHz]
200
205
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
315
320
325
330
335
340
345
350
355
360
365
370
375
380
385
390
395
400
Current
[dB(uA)]
98
97.92
97.75
97.73
97.62
97.54
97.36
97.28
97.26
97.17
97
96.92
96.85
96.84
96.77
96.62
96.59
96.48
96.46
96.3
96.3
96.17
96.09
96.02
95.95
95.98
95.84
95.84
95.79
95.74
95.66
95.52
95.47
95.49
95.42
95.36
95.22
95.24
95.11
95.06
95
15/76
Signal generator Forward power Reflection power
[dB(mW)]
-19.6
-19.6
-19.3
-18.9
-18.5
-18.3
-17.9
-17.3
-17.3
-16.5
-17.1
-16.6
-17.4
-17.3
-18.2
-17.8
-18.7
-18.1
-18.8
-18.5
-18.9
-18.6
-18.8
-18.2
-18.3
-18.2
-18.1
-18.4
-17.9
-18.4
-18.1
-18.9
-18.4
-19
-18.2
-19.1
-18.8
-19.6
-19.1
-19.5
-18.7
[dB(mW)]
31.56
31.55
31.71
31.88
32.03
32.33
32.58
33
33.34
33.4
33.68
33.56
33.52
33.38
32.89
32.79
32.6
32.24
32.44
32.04
31.94
31.94
31.65
31.84
31.77
31.36
31.46
31.49
31.37
31.75
31.38
31.06
31.35
31.22
31.49
31.63
31.02
31.14
31.08
31.03
31.51
[dB(mW)]
19.76
19.11
18.82
22.68
18.69
19.85
22.94
21.4
24.69
24.6
23.44
25.62
24.79
25.02
25.9
23.77
24.4
24.83
23.66
24.94
24.67
22.92
24.4
24.1
23.83
24.68
23.29
23.45
24.27
23.68
24.37
24.1
22.96
24.14
24.01
24
24.52
23.36
23.38
24.35
23.85
Example EMC Facilities Report
16/76
RI 114: RF Immunity, ALSE (except for Radar pulse)
Setup
Inside of ALSE
PowerAmplifierSignalGeneratorPower Meter30001000Ground PlaneSize: 3000 x 1000200Height: 900Antenna positionabove 1000 ulatorCoaxial cableFunctionGeneratorOscilloscope orDigital MultiMeterTestFixture1500Antenna Height: 1000LISNLISN1001000MonitorCamera + -BatteryTV MonitorOptical cable
Example EMC Facilities Report
Photographs
17/76
Example EMC Facilities Report
18/76
Waveform (SG Output)
CW CW (Zoom In)
AM (1kHz 80%)
PM (PRR=217Hz, PD=0.57ms)
0.57ms
217Hz
Example EMC Facilities Report
Calibration data
Calibration Data - 1
Band:
Frequency:
Target field strength:
Polarization:
19/76
4
400-800MHz
100V/m (Level2)
Horizontal
Frequency
[MHz]
400
410
420
430
440
450
460
470
480
490
500
510
520
530
540
550
560
570
580
590
600
610
620
630
640
650
660
670
680
690
700
710
720
730
740
750
760
770
780
790
800
Date:
Anechoic chamber:
Antenna:
Field probe ID:
Operator:
August 18, 2004
No.5
EMCO 3106
104772
Kondo
Field Strength Signal Generator Forward Power Reflection Power
[V/m]
100.3
101.3
100.8
100.2
100.9
100.7
100.4
101.3
100.8
100.1
101.3
100.3
100.8
100.1
101.1
100.9
101
100.6
100.6
101
100.1
100.5
100.4
100.1
100.8
100.8
101
100.2
101.1
100.5
100.5
101
100.8
100.6
101
100
100.9
100.3
100.9
100.4
100.5
[dB(mW)]
-23
-23.3
-23.6
-23.5
-23.2
-22.7
-22.1
-22
-23.1
-23.5
-24
-25.2
-26.8
-27.2
-26.9
-26.4
-26.1
-25.7
-24.8
-25.2
-26
-26
-24.9
-24.7
-26.1
-27.9
-30.1
-30.9
-31
-30.2
-29.5
-29.5
-29.1
-28.5
-28.1
-28.9
-29.4
-30.2
-30.6
-29.8
-29
[dB(mW)]
47.32
46.98
46.48
46.4
46.75
47.3
48.04
48.8
48.31
48.29
48.23
47.15
46.41
46.07
46
46.01
45.88
45.78
46.35
46.1
45.44
45.28
45.81
46.15
45.92
45.47
45.23
45.26
45.15
45.36
45.42
45.14
45.37
44.86
44.81
44.75
44.78
44.47
44.77
44.83
45.42
[dB(mW)]
18.2
27.98
26.12
17.39
32.49
34.1
34.68
35.51
32.35
30
29.1
31.33
27
26.26
20.84
26.85
29.26
23.75
32.5
32.73
32.51
23.84
25.16
26.39
25.55
25.57
27.88
30.34
24.14
29.01
22.07
25.03
27.57
15.48
28.98
23.74
28.72
22.82
29.86
26.34
31.08
Example EMC Facilities Report
Calibration Data - 2
Band:
Frequency:
Target field strength:
Polarization:
[MHz]
400
410
420
430
440
450
460
470
480
490
500
510
520
530
540
550
560
570
580
590
600
610
620
630
640
650
660
670
680
690
700
710
720
730
740
750
760
770
780
790
800
20/76
4
400-800MHz
100V/m (Level2)
Vertical
Field Strength
[V/m]
100.2
100.2
100.5
101
101
101.1
101
100.1
100.3
101.1
100.1
100.5
100.7
100.2
100.4
100.2
100.4
100.6
100.6
100.3
100
100.1
100.2
100.1
100.8
101.4
101
100.3
100
100.6
100.7
100.1
100.4
100.8
100.6
101
100.4
100.1
100.8
100.8
100.8
Date:
Anechoic chamber:
Antenna:
Field probe ID:
Operator:
Signal Generator
[dB(mW)]
-23.1
-23.7
-23.6
-23.4
-23.2
-23.2
-22.8
-23.3
-23.9
-24.5
-25.1
-26
-27.3
-27.7
-26.7
-25.3
-24.1
-23
-22.6
-23.2
-23.1
-23.1
-23.1
-23.7
-25.3
-26.9
-29.2
-30
-29.8
-28.5
-27.8
-28.1
-27.7
-27
-26.7
-27.9
-28.7
-29.1
-29.3
-28.5
-28
Forward Power
[dB(mW)]
47.14
46.52
46.4
46.51
46.76
46.73
47.33
47.5
47.39
47.29
47.08
46.42
45.76
45.65
46.26
47.13
47.86
48.51
48.63
48.19
48.42
48.25
47.67
47.14
46.79
46.44
46.12
46.17
46.38
47.15
47.1
46.56
46.77
46.31
46.28
45.84
45.56
45.56
46.13
46.25
46.4
August 18, 2004
No.5
EMCO 3106
104772
Kondo
Frequency Reflection Power
[dB(mW)]
25.7
25.41
18.08
18.86
33.38
31.95
32.09
33.7
32.49
27.74
27.83
27.72
22.32
27.65
25.75
27.32
30.52
26.49
34.81
34.85
35.37
26.91
28.01
29.73
28.31
22.91
26.62
30.98
26.34
31.21
24.25
26.35
29.11
19.65
30.36
24.91
28.07
20.01
30.31
29.68
33.57
Example EMC Facilities Report
Calibration Data - 3
Band:
Frequency:
Target field strength:
Polarization:
21/76
5
800-1000MHz
70V/m (Level2)
Horizontal
Date:
Anechoic chamber:
Antenna:
Field probe ID:
Operator:
November 2, 2004
No.5
EMCO 3106
104772
Suzuki
Frequency
[MHz]
800
810
820
830
840
850
860
870
880
890
900
910
920
930
940
950
960
970
980
990
1000
Field Strength
[V/m]
70.1
70.6
70.1
70.4
70
70.1
70.3
70.4
70
70.5
70.2
70.4
70.2
70
70.8
70.2
70.7
70.1
70.3
70.1
70
Signal Generator
[dB(mW)]
-32.3
-31.5
-31.5
-30.7
-30.9
-31.4
-30.7
-29.6
-29.5
-29.4
-30.1
-31
-30.6
-30.3
-28.9
-28.8
-28.3
-27.8
-29.2
-28.9
-26.3
Forward Power
[dB(mW)]
42.03
42.79
43.12
43.39
42.76
42.4
42.32
42.99
43.69
44.4
44.43
44.12
44.66
44.56
45.22
45.31
45.54
45.45
44.98
45.19
45.37
Reflection Power
[dB(mW)]
20.97
25.15
22.6
25.97
24.62
19.26
26.69
24.61
26.52
24.19
26.66
24.23
31.63
21.74
31.16
26.73
28.26
29.43
27.17
24.88
27.04
Example EMC Facilities Report
Calibration Data - 4
Band:
Frequency:
Target field strength:
Polarization:
22/76
5
800-1000MHz
70V/m (Level2)
Vertical
Date:
Anechoic chamber:
Antenna:
Field probe ID:
Operator:
November 2, 2004
No.5
EMCO 3106
104772
Suzuki
Frequency
[MHz]
800
810
820
830
840
850
860
870
880
890
900
910
920
930
940
950
960
970
980
990
1000
Field Strength
[V/m]
70.3
70.2
70.2
70.1
70.3
70.3
70.8
70
70.1
70
70.1
70.1
70.6
70.2
70
70.7
70.1
70.5
70.4
70.1
70.9
Signal Generator
[dB(mW)]
-31.3
-30.9
-30.9
-30.5
-29.7
-28.7
-28.5
-28.3
-28.7
-29
-28.8
-29.4
-29.3
-29.6
-29
-28.9
-28.6
-27.4
-29.1
-29.4
-26.9
Forward Power
[dB(mW)]
43.04
43.43
43.7
43.65
44.09
45.08
44.63
44.31
44.45
44.84
45.76
45.81
45.93
45.25
45.17
45.15
45.31
45.87
45.06
44.68
44.84
Reflection Power
[dB(mW)]
28.02
27.66
22.03
24.11
24.6
29.37
26.72
22.89
26.28
22.89
31.16
23.47
32.68
20.4
29.7
27.99
29.74
31.24
26.39
22.81
26.99
Example EMC Facilities Report
Calibration Data - 5
Band:
Frequency:
Target field strength:
Polarization:
23/76
5
1000-2000MHz
70V/m (Level2)
Horizontal
Field Strength
[V/m]
1000
1020
1040
1060
1080
1100
1120
1140
1160
1180
1200
1220
1240
1260
1280
1300
1320
1340
1360
1380
1400
1420
1440
1460
1480
1500
1520
1540
1560
1580
1600
1620
1640
1660
1680
1700
1720
70.8
70.8
70.1
70.7
70.9
70
70.6
70
70.6
70.6
70.1
70
70.8
70
70.8
70
70
70.6
70.6
70.7
70.1
70.2
70
70.2
70.7
70.6
70.1
70.3
70.7
70.6
70.1
70.1
70.1
70
70
70.1
70
Date:
Anechoic chamber:
Antenna:
Field probe ID:
Operator:
Forward Power
[dB(mW)]
40.79
40.44
40.64
40.28
39.67
39.16
39.21
39.36
39.35
39.37
39.21
39.03
38.62
38.1
37.78
37.42
37.18
36.91
36.61
36.89
37.3
36.42
36.7
35.78
36.45
36.7
36.44
35.89
36.26
36.6
35.97
35.51
35.56
35.21
34.81
34.48
34.29
December 1, 2004
No.5
AT4002
200030
Kondo
Frequency
[MHz]
Signal Generator
[dB(mW)]
-11.3
-11.3
-11
-11.6
-12.1
-12.4
-12.3
-12.1
-12.1
-11.7
-12
-12.3
-12.7
-13.1
-13.3
-13.8
-14.1
-14
-13.9
-13.7
-13.6
-14.4
-14
-14.8
-14
-13.6
-14
-14.4
-13.7
-13.1
-13.7
-14.3
-14.2
-14.6
-14.9
-15.2
-15.1
Reflection Power
[dB(mW)]
31.19
25.17
27.34
25.4
22.44
18.54
13.48
21.68
18.88
23.6
12.91
25.53
19.21
18.05
18.2
22.03
25.3
23.6
24.57
22.11
28.36
20.52
26.55
13.04
24.41
21.12
21.89
19.91
22.82
21.39
21.56
16.58
19.65
13.04
14.74
3.43
11.91
Example EMC Facilities Report
Frequency
[MHz]
1740
1760
1780
1800
1820
1840
1860
1880
1900
1920
1940
1960
1980
2000
Field Strength
[V/m]
70.7
70.9
70
70.9
70.4
70.8
70.1
70.1
70.7
70
70.7
70.2
70.8
70.3
24/76
Signal Generator
[dB(mW)]
-14.2
-14.5
-14.6
-14.4
-14.4
-14.1
-14.1
-14.8
-14.5
-14.4
-14.2
-14.7
-14.2
-13.4
Forward Power
[dB(mW)]
35.16
35.06
34.82
35.06
35.01
35.21
35.02
34.44
34.82
34.77
34.63
34.41
34.86
35.73
Reflection Power
[dB(mW)]
17.57
12.26
18.3
12.05
15.33
4.93
15.2
10.32
17.96
4.37
18.37
6.99
8.87
10.11
Example EMC Facilities Report
Calibration Data - 6
Band:
Frequency:
Target field strength:
Polarization:
25/76
5
1000-2000MHz
70V/m (Level2)
Vertical
Field Strength
[V/m]
1000
1020
1040
1060
1080
1100
1120
1140
1160
1180
1200
1220
1240
1260
1280
1300
1320
1340
1360
1380
1400
1420
1440
1460
1480
1500
1520
1540
1560
1580
1600
1620
1640
1660
1680
1700
1720
70.1
70.3
70.1
70.6
70.6
70.8
70.8
70.1
70.8
70.1
70
70.8
70.1
70.1
70.9
70
70.6
70.5
70.1
70.8
70.2
70
70.2
70.3
70.7
70.7
70
70.9
70
70.7
70.8
70.2
70.3
70.2
70.9
70
70.6
Signal Generator
[dB(mW)]
Date:
Anechoic chamber:
Antenna:
Field probe ID:
Operator:
Forward Power
[dB(mW)]
-9.7
-9.7
-9
-10.3
-11.1
-11.3
-10.7
-10.3
-10.9
-10
-9.6
-10.4
-11.4
-11.1
-11.4
-12
-12
-10.5
-9.9
-10.7
-11.5
-12
-11.6
-12.4
-11.6
-10.7
-11.3
-11
-10.5
-10.4
-9.9
-10.9
-11.9
-11.8
-11.4
-12
-11.4
42.38
42.12
42.56
41.54
40.77
40.26
40.79
41.1
40.54
41.09
41.64
41.03
40.03
40.25
39.77
39.11
39.22
40.36
40.64
39.93
39.49
38.94
39.1
38.14
38.83
39.65
39.2
39.35
39.49
39.25
39.8
38.92
37.87
38.06
38.34
37.67
38.01
December 1, 2004
No.5
AT4002
200030
Kondo
Frequency
[MHz]
Reflection Power
[dB(mW)]
32.67
27.05
29.26
27.54
22.04
17.93
19.27
19.77
19.88
25.33
19.25
26.78
19.7
19.18
22.02
22.98
26.47
26.73
29.68
25.85
30.22
21.96
28.6
17.78
26.91
22.96
23.83
23.98
26.51
24.25
24.42
19.16
21.32
18
20.56
7
12.27
Example EMC Facilities Report
Frequency
[MHz]
1740
1760
1780
1800
1820
1840
1860
1880
1900
1920
1940
1960
1980
2000
Field Strength
[V/m]
70.1
70
70.7
70.8
71
70.1
70.8
70.9
70
70
70
70.7
70.9
70.2
26/76
Signal Generator
[dB(mW)]
-11
-11.9
-11.5
-11.2
-11.2
-11.5
-11.1
-11
-10.5
-10.8
-10.6
-10.4
-10.6
-11.3
Forward Power
[dB(mW)]
38.34
37.65
37.97
38.3
38.25
37.89
38.14
38.32
38.86
38.37
38.22
38.79
38.42
37.95
Reflection Power
[dB(mW)]
19.7
17.36
20.85
13.17
19.92
8.15
17.67
14.05
23.53
13.53
20.41
10.41
13.1
12.41
Example EMC Facilities Report
RI 140: Magnetic field Immunity: Radiating Loop
27/76
Radiating LoopFunctionGenerator5cmDigitalMultimeterLISNAudioAmplifierDUTTestFixtureLISN+Battery-
Photographs
Function Generator Digital Multimeter Audio Amplifier
LISN Test Fixture
DUT
Shunt Resistor
Radiating Loop
Example EMC Facilities Report
Measured Magnetic Field Strength
28/76
Reading
Frequency Test Level
Target
Current
[ A ]
1.5647
0.3961
0.0350
0.0519
0.1055
0.5458
1.1080
Value of
Spectrum
Analyzer
[ Hz ]
50
100
340
500
1,000
5,000
10,000
[ dBpT ]
163.0
151.1
130.0
133.4
139.6
153.9
160.0
[ pT ]
141,253,754
35,756,792
3,162,039
4,689,128
9,519,064
49,271,087
100,021,712
[ dBuV ]
94.5
88.4
77.6
74.2
68.1
54.4
49.0
[ dB ]
69.2
63.4
53.0
59.7
71.9
99.8
111.5
Loop Sensor
Factor
Measured
Magnetic
Field
Strength *1
[ dBpT ]
163.7
151.8
130.6
133.9
140.0
154.2
160.5
*1: Measured Magnetic Field Strength = Reading Value of Spectrum Analyzer + Loop Sensor Factor
Example EMC Facilities Report
RI 130: Coupled Immunity, Inductive
29/76
Setup
TestFixtureWire Harness Fixture ConstructionCross SectionN/C RelayPowerSupply0.56Relay Wire10002000Insulator500Ground PlaneInsulatorDUTGround PlaneWiring HarnessRelay Wire, Wiring Harness: Bare copper wire
RI 150: Coupled Immunity, Charging System
Setup
TestFixtureCurrent ProbeWire Harness Fixture ConstructionCross Section10ohms10002000Oscilloscope6Charging WireAudioAmplifierFunctionGenerator5000.550Ground PlaneDUTGround PlaneWiring HarnessCharging Wire, Wiring Harness: Bare copper wire
50
Example EMC Facilities Report
30/76
Photographs
Wiring Harness Fixture
100 mm of separation
Test Fixture
DUT
DC Power Supply
Twisted Wire
Shielded Wire
NC Relay
Battery
Audio Amp.
Oscilloscope Current Probe
Function Generator
10 ohms
Example EMC Facilities Report
P & B Relay
31/76
Current Probe
Example EMC Facilities Report
Waveform
RI130
RI150
mA/mV
600 Hz
mA/mV
5,000 Hz
32/76
mA/mV
1,000 Hz
mA/mV
10,000 Hz
Example EMC Facilities Report
CI 210: Immunity from Continuous Disturbance
33/76
Setup
0 ohm Resistor for Level 10.25 ohms Resistor for Level 2DUT and wiring harnessare nal GeneratorDCPowerAmplifier
Photographs
Ground PlaneSystem 5200 Test Fixture
DC Power Supply
DC Power
Amplifier
0.25 ohms
Example EMC Facilities Report
Waveform
Level 1
50Hz
600Hz
10KHz
34/76
100Hz
1KHz
Example EMC Facilities Report
Level 2
50Hz
600Hz
10KHz
35/76
100Hz
1KHz
Example EMC Facilities Report
CI 220: Immunity from Transient Disturbance
36/76
Setup
CI220 Pulse A1 - CDC PowerSupplyTransientGeneratorDUTDUT and wiring harnessare PlaneCI220 Pulse D - EDC PowerSupplySignalGeneratorDUTDUT and wiring harnessare PlaneCI220 Pulse GDC PowerSupplySignalGenerator0.7 ohmsDUT and wiring harnessare und Plane
DUT
100 mH
Relay
Example EMC Facilities Report
37/76
D, E, F
DUT
DC Power Supply
G
DUT
DC Power Supply
Example EMC Facilities Report
Waveform
Pulse A1
Pulse A2
Pulse B1
Pulse C
38/76
Pulse A1
Pulse A2
Pulse B2
Example EMC Facilities Report
Pulse D Us
Pulse E Us
Pulse F Us
Pulse G Us
39/76
Pulse D tr
Pulse E tr
Pulse F tr
Pulse G tr
Example EMC Facilities Report
CI 230: Immunity to Power Cycling
40/76
Example EMC Facilities Report
Waveforms
41/76
Waveform A Verification (overall) Waveform B Verification (overall)
Waveform B Verification (intial)
Example EMC Facilities Report
42/76
Waveform C Verification (overall)
Waveform D Verification (overall)
Waveform C Verification (initial)
Waveform D Verification (initial)
Waveform C Verification (end) Waveform D Verification (end)
Example EMC Facilities Report
43/76
Waveform A, B, C, D Verification (overall) Waveform A, B, C, D Verification (intial)
Waveform A, B, C, D Verification (initial)
Waveform A, B Verification (initial)
Waveform A, B, C, D Verification (end)
Example EMC Facilities Report
CI 250: Immunity to Voltage Offset
44/76
Setup
Ground Offset of DUTSignalGeneratorDCAmplifierDUTPowerSupply+-TestFixtureGround PlaneInsulatorGround Offset of Sensor, Module or LoadSignalGeneratorDCAmplifierSensor, Moduleor LoadDUTPowerSupply+-TestFixtureGround PlaneInsulator
Photographs
DUT Ground
Waveform
Example EMC Facilities Report
CI 260: Immunity to Voltage Dropout
45/76
Setup
CI260-A, B & CSignal GeneratorDCPowerAmplifier2 ohmsDUTDUT and wiring harnessare PlaneCI260 - D & ESignal GeneratorDCPowerAmplifierDUTDUT and wiring harnessare PlaneCI260 - FSignalGeneratorDCPowerAmplifier1N/C RelayDUT and wiring harnessare GeneratorDCPowerAmplifier2DUTGround PlaneDCUpAmplifier 1DCUpAmplifier 2T2T3T1T1T2T4Up = 13.5 voltsT1 = 5 secT2 = 100 msecT3 = 2.5 secT4 = 7.4 sec
Example EMC Facilities Report
46/76
Example EMC Facilities Report
Waveform
47/76
Example EMC Facilities Report
CI260-A – 5V
48/76
50ms
Example EMC Facilities Report
49/76
本文发布于:2024-09-21 22:41:17,感谢您对本站的认可!
本文链接:https://www.17tex.com/fanyi/4674.html
版权声明:本站内容均来自互联网,仅供演示用,请勿用于商业和其他非法用途。如果侵犯了您的权益请与我们联系,我们将在24小时内删除。
留言与评论(共有 0 条评论) |